background image

 

© Galvin Engineering Pty Ltd 

 

Version 1, 17 November 2022, Page 

2

 of 

4

 

Product Installation Guidelines 

Version 1, 17 November 2022, Page 2 of 4 

PRE-INSTALLATION - 

MOUNTING DETAILS 

– HOLE CENTRES

 

 

If the mounting holes do not already exist, mark out and drill the holes as shown 
in face plate hole dimensions. Ensure drill to suit suitable mounting methods. 

 

Recommended installation height above floor level is 2 metres (6’6”). Spread 
pattern using mains pressure 500kP as shown in side image 

 

      

 

 

    Spread pattern 

 

INSTALLATION

 

INSTALLATION  COMPLIANCE:  Galvin  Specialised  products  must  be  installed  in  accordance  with  these 
installation instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. 
Water and/or electrical supply conditions must also comply to the applicable national and/or state standards. 
Failing to comply with these provisions shall void the product warranty and may affect the performance of the 
product. 

 

IMPORTANT: 

 

Whilst our product designs take into account a broad range of installation types and surfaces, it 

is important that surfaces which fixtures are mounted to are flat and free from defect. Additionally, ensure any 
protruding  connecting  thread  is  square  to  the  wall  so  that  the  outlet  sits  flat  against  the  wall  when  installed, 
ensuring that there are no gaps between the wall and outlet.  This is especially important when installing product 
ranges  that  have  been  designed  for  correctional  and  health  facilities,  where  special  attention  is  required  to 
minimise ligature points and areas for concealment of contraband. In addition to ensuring the products are fitted 
securely and in accordance with the following instructions, consideration shall be given to the use of non-pick 
mastics such as BASF Sonolastic “Ultra” to ensure a high quality and safe installation. 

FRONT MOUNTING

 

 

 

1. Secure shower assembly 

  Fit the shower assembly into cealing cut out 

spud hole. 

  Secure shower assembly with suitable 

fastenings as shown. 

2. Connect the water line 

  Connect water supply to the inlet. 

  Use suitable sealant to prevent leaks. 

 

 

Summary of Contents for GalvinCare CP-BS

Page 1: ...ate finish for easy cleaning and added durability Lead Safe brass construction IMPORTANT All GalvinCare vandal resistant ceiling mounted shower roses are tested in accordance with AS NZS 3662 and leave our premises in good working order As lead free is not currently defined by law in Australia and New Zealand we have based our definition of Lead Safe on the requirements of s1417 of the USA s Safe ...

Page 2: ...the product IMPORTANT Whilst our product designs take into account a broad range of installation types and surfaces it is important that surfaces which fixtures are mounted to are flat and free from defect Additionally ensure any protruding connecting thread is square to the wall so that the outlet sits flat against the wall when installed ensuring that there are no gaps between the wall and outle...

Page 3: ...nstallation Guidelines Version 1 17 November 2022 Page 3 of 4 TESTING Turn on water supply inspect the shower and check for any leaks Note Never operate without a flow restrictor as GalvinCare Vandal Resistant Shower Rose will deliver full mains pressure with unrestricted flow ...

Page 4: ...ilable for download from www galvinengineering com au Galvin Engineering Pty Ltd expressly warrants that the product is free from operational defects in workmanship and materials for the warranty period as shown on the schedule in the manufacturer s warranty During the warranty period Galvin Engineering will replace or repair any defective products manufactured by Galvin Engineering without charge...

Reviews: