background image

 CAUTION:  PRODUCT IS FRAGILE.  TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE!

NOTE: 

For proper operation the recommended working pressure is between 25 psi at valve when flushing and 80 psi static.

 

!

INSTALLATION INSTRUCTIONS

CADET 1.6 GPF TWO-PIECE PRESSURE-ASSISTED TOILETS

 - Model 2462.016 Cadet Elongated 15"
 - Model 2467.016 Cadet Elongated 16-1/2" High Bowl

YORKVILLE 1.6 GPF TWO-PIECE PRESSURE-ASSISTED TOILETS
 

- Model 2876.016 Yorkville Elongated 15"

 - Model 2878.016 Yorkville Elongated 16-1/2" High Bowl

 Thank you  for selecting American Standard - the benchmark of fine quality for over 100 years.  To ensure this product is 
installed properly, please read these instructions carefully before you begin. (Certain installations may require professional 
help.) Also be sure your installation conforms to local codes.

RECOMMENDED TOOLS AND MATERIALS

Putty Knife 

Regular Screwdriver 

Adjustable Wrench 

Sealant   

Tape Measure

Hacksaw 

Wax Ring/Gasket 

Flexible Supply Tube 

Closet Bolts 

Carpenters Level

Closet Flange Set (Cadet Toilets) 

Neoprene or Graphite Felt Gasket (Yorkville Toilets)

1

   REMOVE OLD TOILET

a.   Close toilet supply valve and flush tank completely.  Towel or sponge remaining water from tank and bowl.
b.   Disconnect and remove supply line.  NOTE:

 If replacing valve, first shut off main water supply!

c.   Remove old mounting hardware, remove toilet and plug floor waste opening to prevent escaping sewer gases.
d.   Remove closet bolts from flange and clean away old wax, putty, etc. from base area.
      NOTE: 

Mounting surface must be clean and level

 before

 new toilet is installed!

SAVE FOR FUTURE USE

7 3 0 1 3 1 2 - 1 0 0

P r o d u c t   n a m e s   l i s t e d   h e r e i n   a r e   t r a d e m a r k s   o f   A S   A m e r i c a ,   I n c .
©   A S   A m e r i c a ,   I n c .   2 0 0 9

2-2

3-2

2-1

3-1

DIMENSIONS (Nominal)  

NOTE: 

 Distance from floor to closet 

flange centerline (rough-in) must be 4" (102 mm) with flange 
surface flush to 1/16" (16mm) max. beyond finished wall.

DIMENSIONS (Nominal)  

NOTE: 

 Distance from wall to closet 

flange centerline (rough-in) must be 12" (305 mm)

FOR CADET TOILETS:

FOR YORKVILLE TOILETS:

FLUSH TO
1/16" (16mm)
EXPOSED
CLOSET
FLANGE

CLOSET
BOLTS

168mm
(6-5/8")

PILOT

HOLES

102mm

(4)

346mm

(13-5/8)

Install closet bolts in flange 
channel, turn 90°, and slide 
into place 6" (152 mm) apart 
and parallel to floor. (Use 
putty to hold bolts in place if 
necessary.) Brace under 
flooring as needed and 
drill two mounting pilot 
holes as shown.

INSTALL CLOSET BOLTS

Install closet bolts in flange 
channel, turn 90°, and slide 
into place 6" (152 mm) 
apart and parallel to wall.

INSTALL CLOSET BOLTS

305mm

(12)

CLOSET FLANGE

CLOSET BOLTS

29-3/4"

(752mm)

18-1/2"

(470mm)

20-1/2"

(516mm)

9"

(230mm)

14"

(356mm)

15"

(381mm)

HIGH BOWL

16-1/2"

(419mm)

29-1/4"

(743mm)

HIGH BOWL

30-3/4"

(780mm)

13-5/8"

(346mm)

12"

(305mm)

9"

(226mm)

 1/2"
(11mm)

30-1/4"

(768mm)

20-1/2"

(516mm)

18-1/2"

(470mm)

12"

(305mm)

13-3/4"

(347mm)

9-1/2"

(238mm)

14"

(356mm)

6"

(150mm)

9"

(226mm)

1"

(27mm)

15"

(381mm)

HIGH BOWL

16-1/2"

(419mm)

29-1/4"

(742mm)

HIGH BOWL

30-3/4"

(781mm)

Summary of Contents for 3125.016.020 - 3125.016.020 Yorkville Right Height Pressure-Assisted Elongated Toilet Bowl

Page 1: ... waste opening to prevent escaping sewer gases d Remove closet bolts from flange and clean away old wax putty etc from base area NOTE Mounting surface must be clean and level before new toilet is installed S A V E F O R F U T U R E U S E 7301312 100 P r o d u c t n a m e s l i s t e d h e r e i n a r e t r a d e m a r k s o f A S A m e r i c a I n c A S A m e r i c a I n c 2 0 0 9 2 2 3 2 2 1 3 1 ...

Page 2: ...L WAX SEAL 5 2 INSTALL TOILET ON FLANGE a Unplug floor waste opening and install toilet on closet flange so bolts project through mounting holes b Loosely install retainer washers and nuts Side of washers marked THIS SIDE UP must face up 6 2 INSTALL TOILET a Position toilet squarely to wall and with a rocking motion push bowl against ring and flange Alternately tighten nuts until toilet is firmly ...

Page 3: ... TANK COMPLETE WITH COUPLING COMPONENTS AND RH TANK TRIM TANK COVER BOWL ELONGATED 15 BOWL ELONGATED 16 1 2 H BOWL ELONGATED 15 BOWL ELONGATED 16 1 2 419mm BOLT CAP COVER KIT INCL TWO COVERS WASHERS COUPLING GASKET LOWER SUPPLY ASSEMBLY UPPER SUPPLY ASSEMBLY VALVE CARTRIDGE ASSEMBLY TANK COUPLING KIT BOLTS AND CAPS TANK COVER FOR LOCKING DEVICE COVER LOCKING DEVICE KIT CADET YORKVILLE 7301312 100 ...

Page 4: ...ales receipt This limited warranty does not apply to local building code compliance Since local building codes vary considerably the purchaser of this product should check with a local building or plumbing contractor to insure local code compliance before installation This limited warranty is void if the product has been moved from its initial place of installation if it has been subjected to faul...

Reviews: