background image

 

© Galvin Engineering Pty Ltd 

Version 1, 1 June 2022, Page 

5

 of 

6

 

Product Installation Guidelines 

Version 1, 25

th

 May 2022, Page 

5

 of 6 

8. Fit handle 

 

Ensure the spindle is in the closed 
position and firmly press the lever handle 
onto the spindle in the desired 
orientation. 

 

Check operation of lever handle. It 
should turn freely for a full ¼ turn. 

 

Secure the handle in position using the 
supplied washer and stainless-steel cap 
screw.

 

 

9

.

 Fit water temperature indicator & Test 

 

Once the lever handle is secure; fit the 
appropriate water temperature indicator.

 

 

Check the operation of the unit and inspect 
for any leaks.

 

 

 

TROUBLESHOOTING

 

PROBLEM 

CAUSE 

RECTIFICATION 

Water is not flowing or 
inconsistent flow 

Shower arm is blocked with 
debris. 

Remove debris from shower arm. 

Leak from hose 
connection 

Hose connection loose 

Check wall coupling locates properly with 
hose connection. 

Taps are dripping water 

Ceramic discs are worn or 
damaged 

Remove and inspect SBA. Remove 
debris and/or replace SBA if damaged. 

Tap seat is damaged 

Refurbish tap seat using a reseating tool. 

Water is leaking from 
spindle 

O-ring on jumper valve spindle 
is damaged or worn 

Replace o-ring 

Water is not flowing from 
tap 

Water is turned off 

Turn on water 

Aerator or flow regulator is 
blocked by debris 

Remove aerator and/or flow regulator 
from tap and remove debris. Install an 
inline strainer. 

Spindle is difficult to turn  
 

Build up of scale on spindle, 
spindle worn or o-ring has 
been damaged 

Remove cartridge sleeve, clean and 
regrease. Replace o-ring. Complete SBA 
may need to be replaced. 

Handle is loose 

Screw has come loose 

Tighten handle screw 

Flange does not screw 
down onto wall surface 

Wall bodies are set too far out 

Re-position tap bodies  

 