5. Check Shower for operation and leaks 

Check the hose is securely connected. Turn on 
water supply. Once installation is completed, the 
unit must be tested for any leaks. 
 

Notes: 

1.  To comply with backflow prevention 

standards, the hand spray must hang at least 
55mm above the floor providing 

an ‘air-gap’. If 

the hand piece lies on the floor, then an 
appropriate backflow prevention device must 
be installed.

 

2.  Shown is a Clevakit typical installation 

conforming to AS1428.1-2009.

 

 

For Tapware 
6.

 

Fit spindle assembly

 

 

Remove handle and flange from cartridge 
assembly. Unscrew the ¼ turn ceramic head 
part from the threaded sleeve assembly and 
screw ceramic cartridge into the valve body by 
hand, tighten using a 17mm spanner.

 

 

Refit threaded sleeve and spindle.

 

The ¼ turn ceramic head part MUST be fitted into 
the wall body prior to refitting the threaded 
sleeve and spindle. DO NOT tighten cartridge by 
using the spindle or the threaded sleeve. 
 
 
 
 
 
 
 

 
7. Fit wall flange 

 

Ensure o-ring is fitted to the bottom of the 
wall flange, and then hand-tighten the wall 
flange onto the threaded sleeve.

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 