Exhausting
(external evacuation, Fig. 4.1). Remove any activated carbon filters if present. Kitchen smokes are driven
outside through a flue (not provided with the hood) joined to the exhaust pipe flue connector.
This pipe must not under any circumstances be connected to cooker, boiler or burner exhaust pipes, etc.
Install this flue after completing what described in the INSTALLATION.
The use of pipes and holes on the wall with a smaller diameter than the output of the motor will cause a decrease in
suction performance and an increase of the noise level.
Use as short as possible tubes and with few curves.
Use pipes with smooth internal surfaces
.
Filtering
(inside recycling, Fig. 4.2). The fumes pass through activated carbon filters (not supplied with the hood, Fig.
4.2-A) to be purified and recycled into the kitchen.
V OPERATION
The hood is supplied with a multispeed motor.
The hood should be run at low speed under normal conditions and at higher speeds only when there is a heavy build-
up of fumes or odors.
Ideally, the hood should be switched on as soon as cooking is started and then kept on until all odors have been
eliminated.
The controls (Fig. 5.1) consist of these commands. Press TL to turn on the light, press T1 to switch on the hood at first
speed and to switch off the aspirator, press T2 and T3 to select functioning speeds.
By pressing of the command T1 the motor starts running at the 1st speed. The commands T2 and T3 switch the motor
on respectively at the 2 and 3 speed. In order to switch the motor off press T1 once if set at the 1 speed, twice if set
at the 2 and 3 speed.
V.1 Adjustable and delayed self-switching off
While the hood is working, keep the TL command pressed until all LEDs start blinking.
By pressing one of the commands (T1, T2, T3) you can program the delayed self-switching off, as follows: T1 corresponds
to 5 minutes; T2 corresponds to 10 minutes, T3 corresponds to 15 minutes.
While the self-switching off is in function, it is possible to modify the speed previously set.
If the choice of the switch-
off time corresponds to the set speed, the speed LED flashes, if the choice is different the speed LED remains fixed.
V.2 Filters maintenance reminder
Metal anti-grease filters
Once the hood is switched off, after 30 hour functioning, all the LEDs of the speed buttons switch on with a fixed light
for 30 seconds to remind that metal anti-grease filter need cleaning. To set the timer to zero keep the button T3 pressed
with the aspirator switched off, otherwise the timer will remain set on 30 hour functioning and the reminder will occur
again when the hood is switched off again.
Charcoal filter (for filtering hoods)
Once the hood is switched off, after 120 hour functioning, all LEDs blink for 30 seconds to remind that the charcoal filter
need cleaning.
To set the timer to zero keep the button T3 pressed with the aspirator switched off,
otherwise the timer will remain set on 120 hour functioning and the reminder will occur again when the hood is switched
off again.
VI MAINTENANCE AND CLEANING
Warning! Before any maintenance or cleaning operation, disconnect the hood from the power
supply by setting the main switch of the domestic system to "off".