The minimum distance between the supporting surface of the cooking hob and the lowest part of the range hood must
be not less than 65cm (Fig. 3.1.2).
If the mounting instructions of the gas hob indicate a wider distance, respect it.
It must not be superimposed on stoves with an upper radiating plate.
Respect all the air discharge regulations.
The air must not be discharged in a pipe used to discharge exhaust fumes produced by gas-fed equipment or fuel-fed
equipment.
The room must be adequately ventilated when the hoods is used together with other gas or fuel equipment.
The hood placed above an induction hob can cause condensation, this is a normal phenomenon and not due to
malfunctioning of the product.
The hood is equipped with all the necessary fastenings for its installation, which are suitable for most surfaces. Verify
that the installation surface is strong.
Installation must be carried out by qualified installers according to present regulations.
III.2 Fixing the hood to the wall unit
This type of hood must be installed inside a wall unit and can be mounted on cabinets of different depths (Fig. 3.2.1).
A spacer is supplied with the hood (Fig. 3.2.2) to be applied on the back of the hood. This spacer allows you to install
the hood in a more advanced position. The side of the spacer without fixing holes can be cut to size with a utility knife
(Fig. 3.2.2-B), so keep this in mind when drilling the fixing holes.
The spacer must be fixed with the 3 screws supplied (Fig. 3.2.2-A).
Mark and drill the wall unit as in Fig. 3.2.1. Fix the hood using the 4 screws supplied (Fig. 3.2.1-A)
The front of the drawer can always be aligned with the cabinet, by adjusting the rear of the drawer appropriately. To
adjust, loosen the screws (Fig. 3.2.3), slide the alignment slides (Fig. 3.2.3-A) and retighten the screws.
III.3 Electrical Connection
The electrical connection must be carried out ONLY by qualified technicians.
The electrical protection of the electrical connection upstream of the equipment must comply with the regulations in
force.
Caution! Make sure that the voltage (V) and frequency (Hz) indicated on the serial number plate located
on the appliances correspond to those available at the installation site.
Any change to the electrical installation necessary to install the hood should only be undertaken by qualified staff.
After installation, insulated parts and those carrying electricity must be protected from any possible contact.
Caution! If the electrical connection is carried out incorrectly or not meeting the regulations, it may
damage part of the appliance and the warranty will not be valid.
Warning! Before making the electrical connection, turn the main switch of the domestic system to
"off".
These appliances must be earthed.
Two types of connections to the network are possible:
1.Using a standard plug connected (Fig. 3.3.1) to the power cord and inserted into an accessible
socket outlet (to be disconnected during service operations). Make sure that the plug is accessible
even after the complete installation of the appliance.
2.Stable connection to the network by interposing a bipolar switch to ensure disconnection from the
network, with a contact opening distance allowing complete disconnection under the conditions of
the overvoltage category III, in accordance with the installation rules (Fig. 3.3.2.).
Earth connection (yellow-green wire) should not be interrupted.
If the power cord is damaged, it must be replaced by the manufacturer or its authorized service
center or by a qualified technician, in order to prevent any risk.
IV USE
This cooker hood can be employed as exhausting or filtering.