3. Proper operation
The heat pump is designed for absorbing energy from the air in the room, or
from the area the ducts are connected to, and it transfers the energy to the domestic hot
water accumulator tank.
4. Improper operation
It is prohibited to:
use fat-containing air;
use the device to heat other liquids than domestic hot water.
Install the device:
- outdoors;
- in rooms exposed to freezing;
- in rooms exposed to dust, gases or flammable vapors;
Operate the device:
- with its accumulator tank empty;
- with its coil unfilled;
- at a temperature below +7ºC.
5. Operating principle
Using as a heat pump
During normal use the pump heats 200 liters of water collected in a accumulator tank
up to 45 °C within the following periods.
Air temperature
Cold water temperature
Heating time
+ 20ºC
15ºC
4.5 h
+ 10ºC
15ºC
5.5 h
+ 7ºC
15ºC
6.0 h
Coil
Each heat pump is equipped with one coil used to connect additional heat sources.