(Installer Selectable Options CONT’D)
Two-Tone
Phaser Disable
If desired, the Phaser sound can be replaced with a Two-Tone sound. This can
be done by turning on (up position) DIP switch #3 in the amplifier (labeled SW).
(See Amplifier diagram above)
If desired, the Phaser function can be completely disabled by turning on (up
position) DIP switch #4 in the amplifier (labeled PD).
This will also disable the
manual button while the siren is in Phaser mode
(which normally would
produce a Two-Tone sound).
(See Amplifier diagram above)