background image

What's connected?

The hardware within the kit is pre-wired to support the site's default software configuration.

+

-

+

-

B

A

+

-

B

A

Controller

LAN

IN 16
IN 15
IN 14
IN 13

B

A

GND

VIN

IN 12
IN 11
IN 10
IN 9

OUT 5

OUT 6

OUT 7

OUT 8

Secondary 

8In 4Out 

Board

Reader

Battery 

Low

Mains 

Fail

IN 1

IN 2

IN 3

IN 4

B A

GND VIN

IN 5

IN 6

IN 7

IN 8

OUT

 1

OUT

 2

OUT

 3

OUT

 4

Primary 

8In 4Out 

Board

S

YS

AC

Battery 

(not supplied)

Battery 

(not supplied)

FA

I

N EG L

Main Earth Connection

Mains coming into 

the cabinet

24V 6A Life 

Safety Power 

Supply Unit

12V 4A B100 

Power Supply 

Converter

D8 Fused 

Power 

Distribution 

Board

D1
D2
D3
D4
D5
D6
D7
D8

Earth connected  
to cabinet wall

Alula D7 connection 
Set 

JP7 

to position 2

Earth connected  
to cabinet door

JP1

JP2

JP9

Blk:BAT- 

Red:BAT+

Blk:BR 

Blu:DC1+

Blk:BR J2

Org:B2 J3 

Blu: B1 J1

Blk:BR J3 

Blu:DC in J1

Blk:BR J6 

Org:DC out J5 

Blu: DC in J4

FLEX IO

Summary of Contents for C500306

Page 1: ...00306 Gallagher SMB USA Base Kit T11 Black Reader C500307 Gallagher SMB USA Base Kit T15 White Reader C500308 Gallagher SMB USA Base Kit T15 Black Reader C500309 Gallagher SMB USA Base Kit T30 White R...

Page 2: ...B100 Secondary Voltage Module C305740 1 x Metal Mounting Plate with ducting 1 x Door earth wire 1 x Wiring loom and associated internal cable assembly 1 x Gallagher SMB T15 C500481 480 T11 Reader C50...

Page 3: ...OUT 2 OUT 3 OUT 4 Primary 8In 4Out Board SYS AC Battery not supplied Battery not supplied FAI N EG L Main Earth Connection Mains coming into the cabinet 24V 6A Life Safety Power Supply Unit 12V 4A B10...

Page 4: ...ght or just below i e approximately 1 6 m 5 25 ft from the floor The solution is considered a permanently connected system and is not intended to be moved once installed Dimensions Cabinet Height 620...

Page 5: ...the six mounting holes and rear tamper detector light pipe on the cabinet mounting surface 5 Fix the rear tamper sticker to the mounting surface The sticker must align with the light pipe located in t...

Page 6: ...r connect the orange wire to the green wire Should you require multiple doors the HBUS 8 Port Hub C300698 can be utilized This hub supports the star wiring of eight HBUS devices to the hub s eight por...

Page 7: ...e used for monitoring mains power failure and battery low The remaining 14 inputs can be used to connect sensors The HBUS 16In 16Out Board can be utilized with the SMB Kit to expand the solution Conne...

Page 8: ...voltage in a conjunction with the LifeSafety FPO150 The B100 voltage input is 24 Vdc from the FPO150 and the secondary voltage output is 12 Vdc DC OUT 12 V required for the controller and I O boards a...

Page 9: ...red number of 7 Ah 12 V batteries to the FPO150 To provide 24 Vdc battery backup connect the batteries as shown Battery not supplied Positive Negative Battery not supplied Positive Negative Battery le...

Page 10: ...s below 10 8 V If no battery is connected the Battery Low alarm will not activate This output is connected to Input 7 on the default configuration of the Primary 8In 4Out Board Mains Failure alarm The...

Page 11: ...igned to a site the controller will come online and connect to the cloud An IP address is automatically assigned to the controller via DHCP There is no MAC address or IP addressing required The contro...

Page 12: ...he Gallagher SMB App Note If using tags cards or user codes to arm disarm an area change the Locally disarm area to Single Factor within the Area lightbox 5 Select the Save button The site is created...

Page 13: ...on web page displays 6 Select the required link to configure the Controller as needed 7 When finished set DIP switch 1 to OFF Reset the Controller s IP address then navigate to it If you cannot find t...

Page 14: ...splay advising the Technician to inform the Monitoring station or Guarding company 4 Test buttons will appear next to the Outputs Alarm Relays are bypassed Technicians can chirp test outputs from this...

Page 15: ...250 ms off 400 ms on 250 ms off Boot code monitor running network unplugged Half flash 450 ms on 50 ms off 2Hz flash Controller resetting Fast 130 ms on 130 ms off 4Hz flash Initialising 1 flash 500...

Page 16: ...I O Boards Value 8In 4Out Board operating current 45 mA DC relays OFF 200 mA DC relays ON 8In 4 Out Board power rating 0 61 W relays OFF 2 72 W relays ON Fuse Onboard 1 A resettable polyfuse Reader Va...

Page 17: ...e 5 24 Vdc nominal Current 12 A maximum Standby Current 65 mA Output Voltage Same as input Current D8 3 A Resistive Current D8P 2 5 A Resistive Class 2 Power Limited Fuse D8 Only 3 A ATM automotive st...