User Manual Galileosky Base Block
69
Command format
AccSens Sens,TO
Parameters
Sens – accelerometer sensitivity.
TO – the time after the vehicle stops, during which coordinates are updated, [sec].
Explanation
This function allows avoiding unnecessary outliers after the vehicle stops.
Default value is 40,300.
Sens value equal to 600 is 1g (g –gravitational acceleration)
Example
Request: AccSens 40,300
Reply: Accelerometer sensitive: sens = 40, time out=300
Command format
Ignition N
Parameters
N – an input used as an ignition sensor:
0 – ignition sensor is not used;
1 – input 0 is used as ignition sensor;
2 – input 1 is used as ignition sensor;
3 – input 2 is used as ignition sensor;
4 – input 3 is used as ignition sensor;
Explanation
If there is no response for a given input, vehicle is considered to be not started, and
coordinates are not updated. It allows avoiding outliers after the vehicle stops. Triggering on
input is determined by the limits set by InCfg command (section Analog- discrete inputs
settings).
Example
Request: Ignition1
Reply: IGNITION:1;