Note:
•
For simple troubleshooting, please be sure to disconnect the power supply.
•
For the maintenance and replacement work, please call for professionals or the
maintenance staff from the refrigeration factory of the manufacturer.
•
If the above methods could not solve the problem, please call for professionals.
1. Marble decorative
sheet
2. Side glass
3. Front glass
4. Light tube
5.
Bracket
6. Shelf
7. Air shield
8.
Bottom cover
9. Outlet housing
10. Sliding door
11. Air window
12. Center support
13. Evaporation fan
14. Fan base plate
15. Evaporator
16. Castors
17. Compressor
18. Condenser
19. Control box
Structure Diagram -
WDF series
PROBLEM
CAUSE
SOLUTION
Light failure
Switch off or damaged
Turn on the switch
Wire connection is faulty
Check the plug point
The light power supply
damaged
Replace the light power supply
Light damaged
Replace the light
Too much noise
Unstable placement
Adjust the feet
Loose or damaged screw in
compressor unit or condenser
fan
Tighten or replace the screw