background image

Troubleshooting

continued...

4

PROBLEM

CAUSE

SOLUTION

No power

Damaged fuse

Replace fuse

Bad socket contact

Repair or replace the socket

Damaged power cord

Repair or replace power cord

The compressor

is not running

Temperature controller failure

Replace the temperature 

controller

Loose wire

Check the wire failure

The plug of the starter of the

compressor is loose

Replace the plug

The starter or the capacitor

damaged

Replace the starter or the

capacitor

The compressor is damaged

Replace the compressor

Condenser fan does not

run

Poor fan wiring

Check the wiring of the

condenser fan

Fan motor failure

Replace the motor

Evaporation fan does 

not run

Circuit failure

Check the terminal bus wiring

Fan damaged

Repair or replace the fan

High cabinet 

temperature

Near a heat source

Move the counter or the heat 

source

Frost block

Defrost manually

Over-inventory in the cabinet

which blocks the air outlet and

inlet

Take out part of the goods, move 

that at the air outlet and inlet

Refrigerant leaking

Check the leak and refill 

refrigerant

Condenser contaminated

Clean the dust-hood

Fan failure

Repair or replace the fan

Temperature controller failure

Replace the temperature 

controller

Temperature control probe is

touching the bottom

Reposition the temperature 

control probe

Front glass 

condensation

The defogging switch is closed

or fails

Open and replace the switch

Defogging wire failure

Repair the input and output

wiring

Transformer damaged

Replace the transformer

Summary of Contents for WDF157Z

Page 1: ...INSTALLATION OPERATION AND CARE MANUAL DISPLAY CABINET Imported and distributed by...

Page 2: ...7Z DCG WDF127Z WDF097Z DCG WDF097Z WDF127F DCG WDF127F WDF097F DCG WDF097F WTF160L DCG WTF160L WTF120L DCG WTF120L 1 INDEX 1 Precautions p 2 2 Transport and handling p 3 3 Installation and operation p...

Page 3: ...failure service agent authorized by the manufacturer or professional maintenance staff shall be responsible for the maintenance work in case of danger or expanded failure 6 Do not store explosive subs...

Page 4: ...ng normally Only when the temperature within the cabinet is reduced within the indicated scope can the food be put into the cabinet 5 Don t put too much over hot food in the cabinet to prevent instant...

Page 5: ...fan does not run Circuit failure Check the terminal bus wiring Fan damaged Repair or replace the fan High cabinet temperature Near a heat source Move the counter or the heat source Frost block Defrost...

Page 6: ...f 7 Air shield 8 Bottom cover 9 Outlet housing 10 Sliding door 11 Air window 12 Center support 13 Evaporation fan 14 Fan base plate 15 Evaporator 16 Castors 17 Compressor 18 Condenser 19 Control box S...

Page 7: ...Circuit Diagram WDF series Structure Diagram WTF series 6...

Page 8: ...compressor and the condenser fan motors The most important is the microcomputer controller It is used to set operating parameters To display target set point In programming mode it selects a parameter...

Page 9: ...et point value push the key again or wait 10s How to start a manual defrost 1 Push the key for more than 2 seconds and a manual defrost will start In programming mode it browses the parameter codes or...

Page 10: ...value and move to the following parameter TO EXIT Press or wait 15s without pressing parameter MODEL POWER DIMENSIONS WDF157 Z 0 8kW 240V 1500 x 750 x 1350mm high WDF127 Z 0 7kW 240V 1200 x 750 x 1350...

Page 11: ...10 This instruction manual is an undivided part of the Display Cabinet Please store in a safe place...

Reviews: