Isolated Power High Amp Enable Sourcing Configuration
Isolated Power Low Amp Enable Sourcing Configuration
For Steps 4 and 5 with a DMC-4080 refer to DMC-4080 (Steps 4 and 5) section below.
Appendices ▫ 203
DMC-40x0 User Manual
AEC1 = V-
AEC2 = V+
For +5V to +12V, RP6 = 820 Ω
For +13V to +24V, RP6 = 4.7 kΩ
From Default Configuration:
1.
Move U4 up one pin location on socket
2.
Change JP1 to AEC1
3.
Change JP2 to AEC2
4.
If AEC2 is +13V to +24V, Replace RP6 with 4.7K
Resistor Pack
AEC1 = V-
AEC2 = V+
For +5V to +12V, RP6 = 820 Ω
For +13V to +24V, RP6 = 4.7 kΩ
From Default Configuration:
1.
Move U4 up one pin location on socket
2.
Reverse RP2
3.
Change JP1 to AEC1
4.
Change JP2 to AEC2
5.
If AEC2 is +13V to +24V, Replace RP6 with 4.7K
Resistor Pack