17
SPA YARD
Steps to raise the value of the water temperature above 40º C:
•Use the
key to set the value at 40º C.
•Hold down the
key for 5 seconds: the display will show Or0.0, where 0.0 represents the value to be
programmed.
•Press the
keys to change the value (value between Or0.5 and Or2.0).
•To exit the programming, press any key other than
or wait for 5 seconds.
To change the value, simply press the
keys without leaving the range of Or0.5 / Or2.0 (it is not
necessary to hold down the key for 5 seconds).
To reset a value to within the normal limits:
•Press the
key until you reach the minimum value (display Or0.0).
This function controls the activation of the functions so they do not exceed the maximum value of 32A:
•If the total power of the required functions is less then the permitted maximum, the control activates the
required load.
•If total absorption is above the permitted maximum:
-If the heater is on, it will be switched off to allow the activation of the required functions.
-If the heater is off and there is not enough power available, one of the activated loads will be switched off
to satisfy the user's request.
N.B.:
If the heater is off (interrupted) to enable the activation of a load, the system will try to restart it every 5
minutes.
This system (winter mode) is activated to prevent the water in the pipes from freezing in extreme weather
conditions. It consists of switching on the pumps for one minute periods. The intervals vary according to
the room temperature.
The winter mode status is indicated on the display by the word "ICE".
The following table shows the frequency of the pump activation:
2.4. SAFETY FUNCTIONS
The Spa is equipped with the following safety functions:
2.4.1. MAXIMUM ABSORBED CURRENT
2.4.2. FREEZE PREVENTION (ICE)
AMBIENT TEMPERATURE
FREQUENCY (MINUTES)