NOTHING WORKS. 

1. Make sure there is voltage at  the entry to the machine, if

not the tapping must be changed. It is advisable to see if any

magnetothermal has "blown".

The  machine  has  no  voltage  in  one  or  all  its 

vital elements.

 

2. Check  the  power  source  fuses  situated  on  the  central

panel.   (See Spare parts Sheet)
3. The  machine  panels  must  be  removed  testing  the  logical

points of the electrical diagram.

LIMITER TRIPS

 

Magnetothermal  switch  has  low  gauge  for  the 

case.  There  may  be  a  short  circuit,  which  is 

what causes the limiter to trip.

 

   Change  the  magnetothermal  for  another  larger  gauge 

one. It is important for the magnetothermal switch to have a  

characteristic slow type curve. In the event tha t the electrical 

installation  has  limited  power  the  welding  work  must  be 

tested at lower current levels.

 

IT CAUSES NOISE

 

Loose metal casing.

 

Review and screw casing.

 

Defective electrical connections. 

Correctly tighten the connections.

 

Damaged or poorly attached fan.

 

Examine the fan. 

IF THE GREEN INDICATOR LD1 

IS ON THE APPLIANCE DOES 

NOT WELD

 

Active  protection  system.    Amber  light  “LD2” 

on. 

 

Equipment overheated, wait until the equipment cools down.

 

Supply voltage outside rated margin. Change supply tap. 

THE ELECTRODE BURNS IN TIG 

WELDING

 

Excessive  welding  intensity  for  a  certain 

electrode. 

 

Decrease  welding  current  or  change  electrode  for  one  with 

larger diameter.

 

Use of reverse polarity. 

Place electrode to negative pole.

 

Lack of protection gas.

 

Regulate at an appropriate flow. 

THE EQUIPMENT HEATS UP 

ABNORMALLY. 

THE THERMAL PROTECTION 

ACTIVATES QUICKLY. 

The  equipment  is  positioned  so  that  it  prevents 

correct ventilation.

 

Place  the  equipment  in  an  area  where  the  air  is  constantly 

replaced.

 

The fan does not work. 

Replace the fan. 

The  equipment  is  located  in  a  very  hot 

environment.

 

Avoid positioning where there is direct exposure to the sun. 

There  is  a  loose  connection  inside  the 

equipment. 

 

Review the power electrical connections.

 

ALTHOUGH THE MACHINE IS 

CONNECTED AND WITH THE 

SWITCH LD1 ON, THERE IS NO 

REACTION WHEN PRESSED

 

Failure  of  the  pistol  switch  which  does  not 

make perfect contact.

 

Change the gun microswitch.

 

WHEN THE GUN IS PRESSED, 

ALTHOUGH WIRE COMES OUT, 

THE CONTACTOR DOES NOT 

WORK OR/AND THERE IS NO 

SHIELDING GAS

 

Electrical failure o solenoid vale faulty. 

It  must  be  established  whether  the  fault  comes  from  the 

electronic board or if it is an electrical connection fault. 

 

Check that solenoid valve coils are not open. 

 

WHEN THE SHIELDING GAS IS 

RELEASED IT CONTINUES 

FLOWING.

 

There  is  impurity  in  the  inside  chamber  of  the 

solenoid  valve  which  prevents  the  piston  from 

closing completely.

 

Dismantle and clean the electrovalve.

 

WHEN FINISHING WELDING 

THE WIRE REMAINS STUCK TO 

THE TORCH CONTACT TUBE.

 

Welding  with  the  nozzle  very  close  to  the  part 

to be welded. 

 

Correct the distance to the welding piece

 

WHEN FINISHING WELDING 

THE FINAL WIRE LENGTH IS 

VERY GREAT.

 

The torch is withdrawn immediately when torch 

pushbutton is no longer pressed.

 

The  final  wire  length  control  system  requires  the  welding 

torch  not  to  be  immediately  withdrawn  when  the  torch 

pushbutton is no longer pressed.

 

THE EQUIPMENT DOES NOT 

WELD CORRECT.  

"IT ADJUSTS BADLY"

 

Low effective welding voltage. Output wave not 

correct.

 

Check that there is not a phase failure in the supply power. 

Check  that  the  electrical  contact  elements  of  the  welding 

circuit are correct: Welding mass, rusty or very dirty surfaces, 

contact nozzle with greater diameter than the wire, etc.

 

Test  the  electrical  diagram  of  the  power  source.    Input  and 

output voltages to the rectifier.

 

The  welding  wire  has  a  mechanical  resistance 

at  the  outlet,  which  prevents  it  from  having  a  

regular speed.

 

Examine  the  welding  gun.  Blow  the  inside  (cable)  with 

compressed air. 

 

THERE ARE MANY PROJECTIONS 

IN THE WELDING PROCESS

 

Unsuitable shielding gas.

 

When  welding  normal  steels  we  advise  the  use  of  a  gas 

mixture Ar-CO2.

 

Summary of Contents for Gala 2000 MP

Page 1: ...TR LE AUTOMATIQUE DE SOUDAGE MIG MAG Ref 543 00 000 GALA 2000 MP 230V 50 60Hz E ESTE EQUIPO DEBE SER UTILIZADO POR PROFESIONALES EN BENEFICIO DE SU TRABAJO LEA ATENTAMENTE ESTE MANUAL GB THIS EQUIPMEN...

Page 2: ...LATION 17 3 START UP OPERATION AND ADJUSTMENT CONTROLS 18 3 1 OPERATING CONTROLS 18 3 2 MIG MAG WELDING Installation and start up 19 3 3 TIG WELDING Installation and start up 21 3 4 MMA WELDING Instal...

Page 3: ...r it without any additional charge unless the damage caused to the product is the result of accidents improper use negligence inappropriate accessories unauthorized servicing or modifications to produ...

Page 4: ...de regulaci n MIG MAG I2min I2max 25 200 A Intensidad m xima proceso MIG MAG I2max 200 A 45 de hilo aplicables mm 0 8 1 0 mm Velocidad hilo m min 1 5 16 m min Bobinas rollo de hilo 15 Kg Margen de reg...

Page 5: ...m tica RECOMENDADOS PARA USO MEDIANTE PROCESO TIG 19051704P Antorcha TIG SR 17 V 4m 37600000 Manorreductor Arg n Mod EN 2 5777 Pantalla electr nica autom tica RECOMENDADOS PARA USO MEDIANTE PROCESO MM...

Page 6: ...RUPTOR DIFERENCIAL 2P 25A 300 mA INSTALACI N INDUSTRIAL CLAVIJA MANGUERA BASE Y PROTECCI N EL CTRICA CETAC 2P T 32A BASE 2P 32A TT INTERRUPTOR MAGNETOT RMICO 2P 25A 230V INTERRUPTOR DIFERENCIAL 2P 25A...

Page 7: ...olo negativo E Conexi n cambio de polaridad F Eje soporte carrete hilo bobina de 15 Kg Control de presi n de giro Puede regularse la resistencia al giro mediante el sistema de presi n central G Maneta...

Page 8: ...ADURA MIG MAG INSTALCI N Y PUESTA EN MARCHA 3 2 1 INSTALACI N DEL SISTEMA MIG MAG STANDARD CON GAS ANTORCHA A POSITIVO MARCA REF DESCRIPCI N OBSERVACIONES 1 54312029 Cable de entrada INCLUIDO 2 121403...

Page 9: ...por la sirga de grafito con la antorcha totalmente estirada 5 Seg n el di metro del hilo colocar la ranura de la rueda arrastradora adecuada al trabajo que va a desarrollar 6 Elegir el gas adecuado al...

Page 10: ...jada 5 Montar el manorreductor y conectar el tubo del gas comprobando que ste no tiene p rdidas a lo largo de todo el circuito 3 4 SOLDADURA DE ELECTRODO REVESTIDO MMA INSTALACI N Y PUESTA EN MARCHA 3...

Page 11: ...la m quina espere a que el sistema de refrigeraci n interior la enfr e totalmente MANTENGA EN BUENAS CONDICIONES DE USO LOS ACCESORIOS DE SOLDADURA UNA VEZ FINALIZADA LA OPERACI N DE SOLDEO EVITEEL C...

Page 12: ...azar ventilador El equipo esta situado en un ambiente muy c lido Evite un emplazamiento en donde la exposici n al sol sea directa Existe interiormente una conexi n floja Revisar conexiones el ctricas...

Page 13: ...rija operativa de fin de arco Evite cebar una longitud final de hilo excesivamente larga LA INTERVENCI N SOBRE EL EQUIPO DEBE SER REALIZADA POR PERSONAL ESPECIALIZADO TANTO AL COMIENZO COMO AL FINAL D...

Page 14: ...mismo puede suceder con aquellos materiales que incorporen alg n tipo de tratamiento superficial cincado galvanizado etc Ev tese en todo momento la inhalaci n de los humos desprendidos en el proceso...

Page 15: ...n U2max 15 24 V Continuous MIG MAG adjustment margin I2min I2max 25 200 A MIG welding intensity l2 200 A 45 Applicable wire diameters mm 0 8 1 0 mm Wire reels 1 5 16 m min Wire speed m min 15 Kg Conti...

Page 16: ...G Gala 2500 torch 4mts 5777 Automatic electronic shield RECOMMENDED IN TIG PROCESS 19051704P TIG SR 17 V torch 4m 37600000 Argon pressure reducing valve Mod EN 2 5777 Automatic electronic shield RECOM...

Page 17: ...KET AND ELECTRICAL PROTECTION DEVICES CETAC 2P T 32A SOCKET 2P 32A TT MAGNETOTHERMAL SWITCH 2P 25A 230V DIFFERENTIAL CIRCUIT BREAKER 2P 25A 300 mA The connection to the mains is made by the input hose...

Page 18: ...n C Positive pole D Negative pole E Change of polarity F Support axle for wire reel 15 kg Rotation pressure control The rotation resistance can be adjusted by means of the central pressure system G Ad...

Page 19: ...OF STANDARD MIG MAG SYSTEM WITH GAS TORCH TO POSITIVE POLE MARK REF DESCRIPTION OBSERVATIONS 1 54312029 Input cable INCLUDED 2 12140301210 Wire reel V 0 6 0 8 mm 3 12140301211 Wire reel V 0 8 1 0 mm I...

Page 20: ...e and the wire guide tube for the graphite cable with the torch totally stretched 5 Depending on the wire diameter fit the groove of the suitable driving wheel to the work to be carried out 6 Choose s...

Page 21: ...astened 5 Install the pressure reducing valve and connect gas hose checking that there are no leakages throughout the whole circuit 3 4 COATED ELECTRODE WELDING MMA INSTALLATION AND START UP 3 4 1 MMA...

Page 22: ...hed the work do not disconnect the machine immediately wait until the inner cooling system has totally cooled it KEEP THE WELDING ACCESSORIES IN GOOD CONDITIONS FOR USE ONCE THE WELDING OPERATION HAS...

Page 23: ...environment Avoid positioning where there is direct exposure to the sun There is a loose connection inside the equipment Review the power electrical connections ALTHOUGH THE MACHINE IS CONNECTED AND W...

Page 24: ...oo long Correct arc end operation Do not strike too long a final wire length SPECIALIZED PERSONNEL MUST CARRY OUT ANY WORK ON THE EQUIPMENT BOTH AT THE BEGINNING AND END OF A REPAIR CHECK THE EQUIPMEN...

Page 25: ...also occur with those materials which have some kind of surface coating zinc plated galvanised etc Avoid inhaling the fumes given off in the process at all times Protect yourself from the fumes and m...

Page 26: ...e continu MIG MAG I2min I2max 25 200 A Intensit I2 de soudage MIG 200 A 45 Diam tres de fil applicables mm 0 8 1 0 mm Bobines de fil 1 5 16 m min Vitesse du fil m min 15 Kg Marge de r glage continu MM...

Page 27: ...ronique Prof Automatique RECOMMAND S POUR PROC D TIG 19051704P Torche TIG SR 17 V 4m 37600000 D tendeur Argon Mod EN 2 5777 cran lectronique Prof Automatique RECOMMAND S POUR PROC D MMA 259040 Accesso...

Page 28: ...NT ET SYST ME DE PROTECTION DU R SEAU LECTRIQUE CETAC 2P T 32A SOCLE DE PRISE DE COURANT 2P 32A TT INTERRUPTEUR MAGN TO THERMIQUE 2P 25A 230V INTERRUPTEUR DIFF RENTIEL 2P 25A 300 mA Le branchement au...

Page 29: ...le n gatif E Changement de polarit F Axe support pour bobine de fil 15 kg Contr le de pression de rotation La r sistance de rotation peut tre r gl e au moyen du syst me de pression centrale G Manette...

Page 30: ...rance 3 2 SOUDURE MIG MAG INSTALLATION ET MISE EN PLAC 3 2 1 INSTALLATION DU SYSTEME MIG MAG STANDARD AVEC GAZ TORCHE AU POSITIF MARQUE REF DESCRIPTION OBSERVATIONS 1 54312029 C ble d entr e INCLUS 2...

Page 31: ...nger le c ble et le tube guide fil par un c ble en graphite et une torche stri e 5 Selon le diam tre du fil poser la rainure de la roue d entra nement adapt e au travail qui va tre r alis 6 Choisir un...

Page 32: ...st bien fix e 5 Monter le d tendeur et brancher le tuyau du gaz en v rifiant s il n y a pas de fuites tout au long du circuit 3 4 SOUDURE D ELECTRODE REV TU MMA INSTALATION ET MISE EN PLACE 3 4 1 INST...

Page 33: ...ent la machine et attendre que le syst me de r frig ration int rieur la refroidisse compl tement MAINTENIR LES ACCESSOIRES DE SOUDAGE EN BON TAT UNE FOIS L OPERATION DE SOUDAGE FINIE EVITER LE CONTACT...

Page 34: ...t situ dans une ambiance tr s chaude viter un emplacement expos directement au soleil Il y a un branchement int rieur d tach R viser les branchements lectriques de puissance AVEC LA MACHINE EST BRANCH...

Page 35: ...ue Corrige l op ration de la fin de l arc vite l amor age d une longueur finale de fil trop longue L INTERVENTION SUR L QUIPEMENT DOIT TRE R ALIS E PAR UN PERSONNEL SP CIALIS AUSSI BIEN AU D BUT QU LA...

Page 36: ...ge d gageant une fum e qui peut tre tr s toxique Ceci peut galement arriver avec le mat riel qui a re u un traitement zingage galvanisation etc viter tout moment l inhalation des fum es de soudage Uti...

Page 37: ...KING ELECTRICAL DIAGRAMS PARTS DRAWINGS AND REFERENCE LISTS FORMULA FOR MAKING ORDERS FOR SPARE PARTS Indicate 1 Machine Reference and Serial no 2 Supply Voltage Frequency 3 No of parts description an...

Page 38: ...AND SALE OF AUTOGENOUS AND ELECTRIC WELDING APPLIANCES AND ELECTROMECHANICAL CONSTRUCTIONS FABRICATIONETVENTED APPAREILSDE SOUDAGE AUTOG NE LECTRIQUEET CONSTRUCTIONS LECTROM CANIQUES CENTRAL Jaime Fer...

Reviews: