3.2.2 INSTALLATION OF (FCAW) MIG/MAG SYSTEM WITHOUT GAS. TORCH TO NEGATIVE POLE.
MARK
REF.
DESCRIPTION
OBSERVATIONS
1
54312029
Input cable
INCLUDED
7.1
880015P
MIG Ga la 1500 torch 4mts.
7.2
880025P
MIG Ga la 2500 torch 4mts.
9
53112219
Earth clamp cable
CONNECTED TO POSITIVE
12
54312560
Change of polarity cable
CONNECTED TO NEGATIVE
13
12140301221 Wire reel 0,8-1,0
For tubula r wire
3.2.3. MIG/MAG SYSTEM START-UP.
1) Make sure the ma ins voltage is 230 V.
2) Connect supply ca ble with the suitable plug to the relevant single-phase ta p. See section 2.2.
3) Cha nge the polarity if it is necessary. The torch must be to positive in MIG/MAG with gas process.
4) If the material to be welded is aluminium, change the flexible ca ble and the wire guide tube for the gra phite cable
with the torch tota lly stretched.
5) Depending on the wire dia meter, fit the groove of the suitable driving wheel to the work to be carried out.
6) Choose suitable gas to wire type to be welded. If it has a mobile worksta tion, check tha t the gas bottle is securely
held by the bottle-holder system. Above all check that the safety chain is perfectly fastened.
7) Install the pressure-reducing valve and connect gas hose checking tha t there are no leaka ges, throughout the
whole circuit.
8) Fit the wire reel into the support axle.
9) Fit the welding wire into the driving system. Do not force the wire pressure ha ndle, as if this is too tight, the motor
remains on overload a nd does not rea ch the maximum speed, a nd if the handle is too sla ck, the wire could slip.
10) Once the wire has been fitted, we can then conect the MIG/MAG torch. The wire is loa ded into the torch via the