Operation
Model L3149B C200 Advanced Desk Set
22
A typical printout supported by the C200 is shown below. For these examples, the desk set’s unit ID is
assumed to be 5678; the target unit’s ID is assumed to be 1234. The Line column and line numbers are
added for discussion below.
Line
I/O ORIGIN DESTINATION
TIME DATE
FUNCTION
STATUS
1
O 5678
12:52:23
AM
04-29-99
PTT
ID
2
I 1234
5678 12:52:41
AM
04-29-99
PTT
ID
3
O 5678
1234 12:52:52
AM
04-29-99
SEL
CAL
4
I 1234
5678 12:53:07
AM
04-29-99
SEL
CAL
5
O
5678
1234
12:53:24 AM
04-29-99
CAL ALT
6
I
1234
5678
12:53:25 AM
04-29-99
ACK
CAL ALT
7
O
5678
1234
12:54:10 AM
04-29-99
CAL ALT
8
O
5678
1234
12:54:14 AM
04-29-99
CAL ALT
RETRY
9
O
5678
1234
12:54:18 AM
04-29-99
CAL ALT
RETRY
10
O
5678
1234
12:54:21 AM
04-29-99
CAL ALT
RETRY
11
O
5678
1234
12:54:25 AM
04-29-99
CAL ALT
RETRY
12
O
5678
1234
12:54:29 AM
04-29-99
CAL ALT
FAIL
13
I
1234
5678
12:54:51 AM
04-29-99
CAL ALT
14
O
5678
1234
12:54:51 AM
04-29-99
ACK
CAL ALT
15
O 5678
1234 10:55:11
AM
04-29-99
RAD
CHK
16
I
1234
5678
10:55:12 AM
04-29-99
ACK
RAD CHK
17
O 5678
1234 10:56:06
AM
04-29-99
EMRGNCY
18
I 1234
5678 10:56:07
AM
04-29-99
ACK
EMRGNCY
Line 1 shows an outbound or desk set-initiated PTT ID. Line 5 shows an outbound Call Alert. Line 6
shows the inbound acknowledgment for the Call Alert on line 5.
Lines 7 through 12 show an outbound Call Alert that did not receive an acknowledgment. Line 12 shows
that the Call Alert failed. If during the retry sequence, the operator terminated the Call Alert, the status
would show ABORT.
If an alias of “SHERIFF” is programmed for the unit ID 1234, the printout contains the alias name instead
of the actual unit ID as seen below.
Line
I/O ORIGIN DESTINATION
TIME DATE
FUNCTION
STATUS
1
O 5678
01:00:17
AM 04-29-99 PTT
ID
2
I SHERIFF
5678
01:00:25
AM 04-29-99 PTT
ID
RS-232 Input or PC Control
The RS-232 input feature allows a computer to send information, which causes the desk set to initiate a
MDC1200 message, page (without talk time), frequency change or custom tone transmission.
In order for the desk set to expect data from the RS-232 port and lock-out the desk set keyboard, a “^”
(caret) and a <CR> (carriage return) must be sent to the desk set. If the desk set is not currently busy and
in normal operation, it returns the ASCII string “018”. At this point, control of the desk set from the front
panel is not possible; however, it is recommended that the keyboard not be used during a PC direction of
the unit. After the PC has received the “018”, data may be sent to the desk set.
The functions of PC Control are described below. Note that all bytes are represented in ASCII format.
Summary of Contents for L3149B
Page 77: ...71 Schematics ...
Page 78: ...Schematics Model L3149B C200 Advanced Desk Set 72 DeskSetLineInterfaceSchematicDiagram Sheet1 ...
Page 79: ...Model L3149B C200 Advanced Desk Set Schematics 73 DeskSetUserAudioI OSchematicDiagram Sheet2 ...
Page 81: ...Model L3149B C200 Advanced Desk Set Schematics 75 DeskSetDSPBlockSchematicDiagram Sheet4 ...
Page 82: ...Schematics Model L3149B C200 Advanced Desk Set 76 DeskSetToneKeypanelSchematicDiagram Sheet5 ...
Page 83: ...Model L3149B C200 Advanced Desk Set Schematics 77 DeskSetPowerSupplySchematicDiagram Sheet6 ...
Page 85: ...Model L3149B C200 Advanced Desk Set Schematics 79 RelayI OOptionSchematicDiagram XRC0001A ...
Page 86: ...Schematics Model L3149B C200 Advanced Desk Set 80 NOTES ...
Page 87: ...81 Circuit Boards ...
Page 88: ...Circuit Boards Model L3149B C200 Advanced Desk Set 82 MainUnitDTDCircuitBoard ...
Page 89: ...Model L3149B C200 Advanced Desk Set Circuit Boards 83 MainUnitPowerandLineCircuitBoard ...
Page 90: ...Circuit Boards Model L3149B C200 Advanced Desk Set 84 RelayI OOptionCircuitBoard ...
Page 92: ...Notes Model L3149B C200 Advanced Desk Set 86 ...