Model L3149B C200 Advanced Desk Set
Programming
61
Configure MDC1200
MDC Feature Order
This feature allows you to select which manual paging types or MDC types will be available on the
C200. You may also determine the order in which the selected paging types appear.
N
OTE
:
Paging types enabled have no effect on which MDC types are available in any part of the
programming software. All paging and MDC types will be available.
To Enable an MDC Type
Highlight the paging type's name under
Available MDC Types
. More than one may be selected. Click
on the
Add
button. The name(s) moves to the
MDC Types in Use
area. The new entry(entries) are
placed at the end of the list.
To Disable an MDC Type
Highlight the paging type's name under
MDC Types in Use
. More than one may be selected. Click on
the
Remove
button. The name(s) moves to the
Available
MDC Types
area.
To Change the Order of the Selected MDC Types
Highlight only one paging type under
MDC Types in Use
. Click on
Move Up
to place it higher on the
list. Click on
Move Down
to move it lower in the list.
Click on an area of the window for a description of its function.
MDC Pretime Timers
TX Pretime
The
TX Pretime
is the time the desk set waits after the transmission has begun before transmitting the
data. For tone control, the time begins after the end of the function tone. The valid range for this
parameter is
0-2000
ms
in
10 ms
increments.
TX Post Pretime
The
TX Post Pretime
is the time after the
TRANSMIT
button is released, before the desk set transmits a
Post PTT ID if
Post PTT ID
is enabled in the MDC Flags. The valid range for this parameter is
0
to
2000 ms
in
10 ms
increments.
Acknowledge Pretime
The
Acknowledge Pretime
is the time the desk set waits after the beginning of a transmission to
acknowledge the receipt of a MDC message before data is transmitted. For tone control the time begins
after the end of the function tone. The valid range for this parameter is
0
to
2000 ms
in
10 ms
increments.
MDC ID
The
MDC ID
is the RapidCall ID of the desk set. This ID is unique to all units in the same system. It is
used when addressing other units or determining whether a specific RapidCall message is intended for
itself. The valid range is from
0001
to
DEEE
. The ID cannot be 0000, cannot contain a wildcard or F,
and must be less than E000.
Summary of Contents for L3149B
Page 77: ...71 Schematics ...
Page 78: ...Schematics Model L3149B C200 Advanced Desk Set 72 DeskSetLineInterfaceSchematicDiagram Sheet1 ...
Page 79: ...Model L3149B C200 Advanced Desk Set Schematics 73 DeskSetUserAudioI OSchematicDiagram Sheet2 ...
Page 81: ...Model L3149B C200 Advanced Desk Set Schematics 75 DeskSetDSPBlockSchematicDiagram Sheet4 ...
Page 82: ...Schematics Model L3149B C200 Advanced Desk Set 76 DeskSetToneKeypanelSchematicDiagram Sheet5 ...
Page 83: ...Model L3149B C200 Advanced Desk Set Schematics 77 DeskSetPowerSupplySchematicDiagram Sheet6 ...
Page 85: ...Model L3149B C200 Advanced Desk Set Schematics 79 RelayI OOptionSchematicDiagram XRC0001A ...
Page 86: ...Schematics Model L3149B C200 Advanced Desk Set 80 NOTES ...
Page 87: ...81 Circuit Boards ...
Page 88: ...Circuit Boards Model L3149B C200 Advanced Desk Set 82 MainUnitDTDCircuitBoard ...
Page 89: ...Model L3149B C200 Advanced Desk Set Circuit Boards 83 MainUnitPowerandLineCircuitBoard ...
Page 90: ...Circuit Boards Model L3149B C200 Advanced Desk Set 84 RelayI OOptionCircuitBoard ...
Page 92: ...Notes Model L3149B C200 Advanced Desk Set 86 ...