ENGLISH
Pay attention as
the
steam pipe be hot
!
Descaling:
In hard water areas, minerals found in the water
will accumulate and affect operation of the unit.
Approximately every two months (this can vary
depending on use and water condition), clean
the machine with Gaggia descaler (in which
case follow the instructions on the packet).
Remove shower disc (16) and clean.
Pour solution into tank and turn on pump for 15
seconds. Allow solution to flow through brewing
head and steam nozzle for several seconds. Wait
20 minutes, then repeat. process until solution
has been run through.
Rinse machine thoroughly by running plain cold
water through machine. Replace shower disc
(16).
NOTE:
Product failure due to scale
accumulation is not covered by warranty. No
other servicing should be attempted by the user.
Use “Gaggia cleaner” for best results.
3 Wipe body of machine with a damp cloth
as required.
4 Remove drip tray and plate (5-12) and wash
in warm soapy water. Do not use abrasive
substances.
5 Clean the seal (15) inside of the brewing
head (14) and keep it clean.
6 The shower disc (16) should be unscrewed
and cleaned periodically depending on
frequency of use.
7 After long periods of non-use, drain stale
water from machine by turning hot water/
coffee switch to “
1
”. However, do this only
after you have filled tank with fresh water.
Never operate pump unless there is water
in tank.
8
NOTE:
It is very normal for an espresso
machine to emit steam and drip occasionally
as the water pressure changes during use.
Be certain to empty drip tray (12) as
required,
• 13 •