7
REV. 2/23
GB808V POWERUNIT
PRINCIPLE OF OPERATION
Incoming air is regulated between 80
-
100 psi. (5.5
-
6.9 bar) through the air filter / regulator. When the actuator lever assembly is depressed
on the installation tool, pressurized air inside the four
-
way valve is released allowing a plunger to unseat a valve ball allowing the air
to be redirected to the rear of the booster starting the cycle. As the air piston in the booster begins to move forward the air in the front
side is being exhausted out of the muffler and simultaneously forcing hydraulic oil up and into the front side of the head cylinder assembly,
causing the head piston to move to the rear of the head cylinder assembly. The internal components of the attached nose assembly are
also moving with the head piston to start the fastener installation. When the fastener installation is completed, the actuator lever assembly is
released. Air pressure is then built up inside of the four
-
way valve re
-
seating the valve ball that in return directs the air to the front
side of the booster and to the rear of the head cylinder reversing the sequence while vacuuming the spent pintail into the collection bottle.
4 WAY VALVE / HYDRAULIC FLOW
FOUR
-
WAY VALVE
RETURN
PULL
HYDRAULIC FLOW
“
PULL
”
“
RETURN
”
EXHAUSTED
RETURN
PULL
HYDRAULIC FLOW
“
PULL
”
“
RETURN
”
EXHAUSTED AIR
Images may not reflect actual tool
Summary of Contents for GB808V
Page 13: ...13 REV 2 23 GB808V POWERUNIT OVERHAUL BOOSTER ASSEMBLY...
Page 16: ...16 REV 2 23 GB808V POWERUNIT GB808V POWER UNIT GB808V POWER UNIT VACUUM BOTTLE ASSEMBLY...
Page 17: ...17 REV 2 23 GB808V POWERUNIT GB808V POWER UNIT FRAME ASSEMBLY...
Page 19: ...19 REV 2 23 GB808V POWERUNIT This page intentionally left blank...