15
REV 4/22
GB752SR
-
8 INSTALLATION TOOL
REMOVING ACTUATOR ASSEMBLY
-
AIR (704130)
1.
Remove lever assembly (724017) including pin.
2.
With lever assembly (724017) removed, insert a
5/8”
open end box / adjustable wrench around actuator
assembly
-
air (704130).
3.
Loosen the actuator assembly
-
air (704130).
4. Remove wrench. Unthread and remove the actuator assembly
-
air (704130) with fingers from the
manifold
-
head assembly (744306).
INSTALLING ACTUATOR ASSEMBLY
-
AIR (704130)
1.
Apply Teflon® tape onto threads of actuator assembly
-
air (704130) one to two wraps.
2.
Thread the actuator assembly
-
air (704130) all the way into manifold
-
head assembly (744306) with fingers.
3.
Insert and turn
5/8”
open end box / adjustable wrench and snug tight approximately 1/4
-
1/2 turn.
4.
Re
-
attach the lever assembly (724017) with pin.
Image may
not reflect
actual tool.
ACTUATOR ASSEMBLY
-
AIR
WARNING
:
Disconnect tool from its power source before actuator removal or installation. Severe personal injury may occur if
power source is not disconnected.
CAUTION:
Actuator assembly
-
air (704130) can break if not careful.
CAUTION:
Do not over tighten actuator assembly
-
air (704130). Snug tighten only.