background image

Rev. 11/14 

 

S/N: 1090 AND ABOVE  

PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS. 

WARNING

 

Do not pull fastener unless it is placed

 

in an 

assembly, pin will eject forcibly

 

when pintail breaks 

off. Severe

 

personal injury may result. 

WARNING

 

Do not operate without Stat-O-Seal

 

(S572) and 

button head cap screws (402482). Pressurized

 

hydraulic oil may cause severe

 

personal injury.

 

WARNING

 

When operating, repairing or overhauling tool, wear 

approved eye protection. Do not look in front of 

nose assembly or rear of tool when installing 

fastener.

 

WARNING

 

Always disconnect tool from power source before 

performing any maintenance

 

to any tool or nose 

assembly.

 

  

WARNING

 

Do not operate if deflector, bottle,

 

catcher  bag or 

vacuum tube is

 

removed or damaged, broken

 

pintails may eject forcibly from rear of tool. Severe 

personal injury

 

may result. 

CAUTION

 

Ensure that nose assembly and tip

 

are properly 

matched for the

 

fastener being installed. 

CAUTION

 

Keep Nose Assemblies clean and free

 

of chips and 

debris. 

WARNING

 

Be sure there is adequate clearance for

 

tool and 

operator's hands before

 

proceeding. Keep fingers 

clear of any moving parts. Keep fingers clear from

 

fasteners and installed materials.

 

Severe personal 

injury may result.

 

WARNING

 

It is required to use hearing protection. A test was 

carried out in a simulated work environment where 

the background level was 73.2 dB (A). In this 

condition the max level was 81.5 dB (A). Therefore, 

it is required where prolonged use, hearing 

protection be used.

 

CAUTION

 

Do not use beyond the design intent. 

WARNING

 

Tool must be maintained in a safe working 

condition at all times and examined on a daily basis 

for damage or wear. Any repair should be done by 

qualified personnel trained on Gage Bilt 

procedures. 

WARNING

 

Where prolonged use is foreseen, it is 

recommended a tool balancer be used. Check 

suspension device to ensure that it is secure. 

WARNING

 

Do no use tool in explosive atmosphere. 

CAUTION

 

Tool is not to be used as a hammer. 

WARNING

 

Risk of crushing exists if nose assembly is not  

attached. 

WARNING

 

It is recommended tool be operated 50 out of every 

60 minutes, where prolonged use is expected. 

WARNING 

Shock: 

 

It is recommended operator wear a suitable glove 

during operation where prolonged use is expected. 

WARNING 

Air pressure not to exceed 100 psi (6.9 bar). 

SAFETY WARNINGS 

PLEASE READ THIS MANUAL BEFORE  

SERVICING OR USING THIS TOOL.  

  

WARNINGS: 

  

MUST BE UNDERSTOOD TO AVOID 

SEVERE PERSONAL INJURY 

CAUTIONS: 

  

SHOW CONDITIONS THAT WILL 

DAMAGE EQUIPMENT OR STRUCTURE 

WARNING

 

Ensure

 

that all connections are properly secured 

before connecting to power. 

Summary of Contents for GB704

Page 1: ...A GAGE BILT Inc 44766 Centre Court 586 226 1500 Clinton Twp MI 48038 586 226 1505 Fax e mail solutions gagebilt com www gagebilt com GAGE BILT TOOLS ARE AVAILABLE WORLDWIDE S N 1090 AND ABOVE PLEASE...

Page 2: ...I or equivalent Setting stroke 540 13 72 mm Rated pull load 3 300 lbs 14 68 kN Noise level 81 5 dB A Vibration Tested No hazards found TABLE OF CONTENTS Description Page Warnings 3 Principle of Operat...

Page 3: ...ere personal injury may result WARNING It is required to use hearing protection A test was carried out in a simulated work environment where the background level was 73 2 dB A In this condition the ma...

Page 4: ...lic oil up and into the front side of the head cylinder assy causing the piston to move to the rear of the head cylinder assy The internal components of the attached nose assembly are also moving with...

Page 5: ...pping plug from Swivel A 249 and screw in your air fitting 2 Attach Deflector 200232 to rear of Head Cylinder Assy 704183 WARNING Rotate deflector away from operator and other persons working in the v...

Page 6: ...revent wear The tool will eventually lose some hydraulic oil Keep the hydraulic system full only use Dexron III or equivalent and free of air by using the air bleeder assy 704153 on a weekly basis Pro...

Page 7: ...36 towards plug 704313 located on handle assy 704132 Torque button head cap screws A 928 to 40 inch lbs 4 Push piston 704507 full forward Install gasket 704129 o ring S832 and socket head cap screws 4...

Page 8: ...or damaged Hole diameter should be 028 Clear and size or replace 3 NO OPERATION WHEN LEVER ASSEMBLY 724017 IS DEPRESSED a Tool seized due to mechanical failure or damaged parts 4 OIL LEAKAGE a DO NOT...

Page 9: ...plete set of o rings back up rings screws washers and gasket It is recommended that this service kit be kept available for spare parts 704214 STEM CATCHER BAG 704149 PISTON ROD WRENCH 704151 POWER CYL...

Page 10: ...ush against threaded end of piston 704507 to slide it out of head cylinder assy 704183 Be careful not to damage threads or cause burrs on polished piston 704507 surface The re assembly sequence is the...

Page 11: ...nserted into top of power cylinder 751131 To reassemble the handle assy 704132 reverse the above procedure being certain that all o rings are properly lubricated before installation Torque packing plu...

Page 12: ...will be evolved when this material undergoes combustion ACCIDENTAL RELEASE MEASURES Protective Measures Eliminate all sources of ignition in vicinity of spilled material Spill Management Stop the sour...

Page 13: ...715 40OS 1 3 16 6A 704A 16 6A 704 54RA 6A 715 40OS 1 8 32 GS8 704 16 GS8 704 54RA GS8 715 40OS 1 CHERRYMAX CHERRYMAX AB MBC LOCK CREATOR BACR15FR FP BACR15GF GK GAGE BILT CERTIFIES THE GB704 WILL INST...

Page 14: ...ty are reworked or subjected to any type of additional processing This warranty is void if Seller is not notified in writing of any rejections or defects within 6 months after the receipt of the mater...

Reviews: