background image

10

 

2/23 REV 8/23

 

 

 

GB107 20V BATTERY INSTALLATION TOOL 

 

Additional Actuator Assy (VP1572) functions:

 

 

 

 

1.

 

Auto and Manual mode:

 

 

 

 

a.  In Manual mode, hold the actuator assy (VP1572), depressing during setting of the fastener until the mandrel is sheared off.

 

 

 

 

b.  In Auto mode, you only have to press the actuator assy (VP1572) briefly and the installation tool controls the fastening 

 

 

   

process automatically.

 

 

2.

 

To change from one mode to the other, hold the actuator assy (VP1572) pressed for ten seconds (until the white LED on the tool starts 

 

 to flash (2 sec.) and release again. Press the actuator assy (VP1572) briefly and the tool moves to its starting position again.

 

HOW TO SET

-

UP THE GB107 Cont.

 

BELT CLIP (VP1322)

 

SCREW

 

SLOTS FOR BELT CLIP (VP1322) (2X) 

 

Image may not 

 

reflect actual tool

 

Battery (VP1086) Storage:

 

 

1.

 

Protect the battery (VP1086) from moisture and liquids. Do not leave in car e.g. in the summer.

 

 

2.

 

Store the battery (VP1086) only in optimum temperature range between 

-

22°F (

-

30°C) and 77°F (25°C). The batteries can be stored as 

follows without recharging:

 

 

 

 

 

Storage period between 22°F (

-

30°C) and 77°F (25°C)  = 1.5 years

 

 

 

 

 

Storage period between 22°F (

-

30°C) and 113°F (45°C) = 3 months

 

 

 

 

 

Storage period between 22°F (

-

30°C) and 140°F (60°C) = 1 month

 

 

3.

 

A significantly shorter operating time after recharging indicates that the battery (VP1086) is worn out and needs to be replaced. 

 

 

Observe all local disposal procedures.

 

Attaching the Belt Clip (VP1322):

 

 

 

Note: Always ensure belt clip (VP1322) is secure to the installation tool before using.

 

 

1.

 

Attach the belt clip (VP1322) to the foot of the installation tool using the screw. A corresponding thread and slots are recessed in the foot 

of the housing on both sides of the installation tool.

 

 

2.

 

Check at regular intervals that the belt clip (VP1322) is still securely attached. Otherwise, retighten the screw.

 

Summary of Contents for GB107 Series

Page 1: ...ES 20V BATTERY INSTALLATION TOOL ORIGINAL INSTRUCTIONS 44766 Centre Court Clinton Twp MI 48038 USA Ph 1 586 226 1500 Fax 1 586 226 1505 solutions1 gagebilt com www gagebilt com GAGE BILT MADE in USA G...

Page 2: ...ONTENTS Page Warranty 3 Description and Technical Specifications 4 Description of Functions 5 Warnings 6 Principle of Operation 7 How to set up the GB107 8 10 How to use the GB107 11 Maintenance 12 Tr...

Page 3: ...arranty shall be limited to the repair or rework of the goods supplied or replacement thereof at Seller s option and in no case is to exceed the invoice value of said goods Under no circumstances will...

Page 4: ...e V DC 7 0 to 21 0 Charger Output Current Ah 4 Charger Working Temp F C 32 F 104 F 0 C 40 C Charger charging time to 22 30 minutes 90 100 Charger weight w o cable 55 lbs 0 25 kg ENVIRONMENTAL USE WARN...

Page 5: ...ION OF FUNCTIONS Images may not reflect actual tool Nose Tip Mandrel Collection Bottle Actuator Assy Riveting Point Light white LED Battery Lock Release Latch Hanger Hole Battery with charging status...

Page 6: ...o allow counteracting of normal or unexpected movement of the tool 8 If the tool is fixed to a suspension device make sure that fixation is secure 9 Beware of the risk of crushing or pinching if nose...

Page 7: ...end a signal to the motor When the actuator assembly is depressed the gear on the motor spins the gear on the gear box assy retracting the nose assembly collet This action causes the jaws to clamp on...

Page 8: ...nto eyes or burns occur WARNING Do not use in explosive atmosphere WARNING Charge the batteries only in chargers recommended by the manufacturer Risk of fire or explosion if batteries used on non manu...

Page 9: ...ages may not reflect actual tool Preparing the Installation Tool GB107 1 Attach the mandrel collection bottle VP1002 by turning to the right Note Tool will not function without mandrel collection bott...

Page 10: ...battery VP1086 from moisture and liquids Do not leave in car e g in the summer 2 Store the battery VP1086 only in optimum temperature range between 22 F 30 C and 77 F 25 C The batteries can be stored...

Page 11: ...fasteners and installed materials Severe personal injury may result Ensure that there are no electrical cables gas pipes etc which can cause a hazard if damaged by the tool WARNING Do not pull fasten...

Page 12: ...ener type by the maintenance personnel Changing the jaws should be done by the maintenance personnel when the fastener can no longer be set in one stroke Changing the anvil insert should be done by th...

Page 13: ...ool is guarded by a protection circuit Replace the battery with a fully charged one The yellow LED turns off and you can continue working 3 THE INSTALLATION TOOL DOESN T WORK WITH AND THE YELLOW RED L...

Page 14: ...MAND SAFETY SWITCH LEVER SPRING 1 8d VP1570 STANDARD NOSE PIECE 5 0 MM 3 16 1 24 VP1545 COVER TOP LED 1 9 VP1571 UNION RING 1 25 VP1479 DISPLAY PROTECTION 1 10 VP1572 TRIGGER AND PRESSURE SPRING 1 26...

Page 15: ...15 2 23 REV 8 23 GB107 20V BATTERY INSTALLATION TOOL This page intentionally left blank...

Page 16: ...8 Process Monitoring GB108 Blind rivets 3 32 2 4 mm thru 1 4 6 3 mm diameter GB108A Blind rivets 3 32 2 4 mm thru 1 4 6 3 mm diameter Contact Gage Bilt for nose assembly options GB128 1 4 6 3 mm thru...

Reviews: