GB714SH INSTALLATION TOOL S/N: 1003 AND ABOVE
PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS.
OVERHAUL
POPPET VALVE ASSEMBLY (703651)
WARNING
:
Disconnect tool from its power source before poppet valve assembly (703651) removal or installation. Severe
personal injury may occur if power source is not disconnected.
CAUTION:
Use caution when removing the poppet valve assembly (703651) from the handle assembly (700343).
CAUTION:
Ensure all parts are assembled properly and correctly fastened to the tool before using.
REMOVING POPPET VALVE ASSEMBLY (703651)
1.
Remove set screw (401771) and lever (704345) from handle assembly (700343).
2.
Remove pin (703543) from handle assembly (700343).
3.
Pull poppet valve assembly (703651) from handle (700343). If unable to remove by hand, carefully
remove using pliers, being careful not to compromise poppet valve assembly (703651).
INSTALLING POPPET VALVE ASSEMBLY (703651)
1.
After replacing o
’
rings on poppet valve assembly (703651), insert poppet valve assembly (703651) into
handle assembly (700343) (Note direction in image above) and push with thumb until it stops.
2.
Reinsert pin (703543) into hole on handle assembly (700343).
3.
Re
-
attach the lever (704345) and tighten set screw (401771).
Note: View above shows proper orientation of lever.
ASSEMBLY
ASSEMBLY.