APPLICATION INSTRUCTIONS

EcoSmart 

Roof Vent

 POWERED

DUAL

Safety Considerations and Warnings

1.  Use appropriate safety glasses, gloves, hard hats, 

restraints, and other equipment to avoid injury.

2.  Wear durable work gloves while handling the unit  

during installation. This product has sharp edges that  

can cause injury.

3. Observe all applicable building codes in your area.
4.  Do not damage electrical wiring or other hidden utilities 

when cutting or drilling.

5.  Make sure the fan blade is on tight and ensure the set 

screw is securely tightened.

6.  Use this unit only in the manner intended by GAF. 

If you have any questions, please contact Master Flow

®

 

Technical Services at 1-800-211-9612.

7. Ducted fans must always be vented to the outdoors.
8.  

WARNING...

 DUAL POWER SOURCE! TO REDUCE 

THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO 

PERSONS, OBSERVE THE FOLLOWING:

      a)  Installation work and electrical wiring should be 

performed by qualified persons in accordance  

with applicable building codes and standards,  

including codes for fire ratings.

    b) Before servicing or cleaning unit:
     

•  Switch power off at the service panel and take 

all steps necessary to prevent power from being 

switched on accidentally. If the service panel 

cannot be locked, securely fasten a prominent 

warning device, such as a tag, to the service 

panel. 

     

•  Disconnect power leads from solar panel to 

prevent accidental operation.

9.   This fan should be connected to a circuit with minimum 

14-gauge wiring that has at least 3 amperes of available 

capacity. If you cannot confirm that there is sufficient 

electrical capacity on an existing circuit, install a separate 

dedicated circuit. DO NOT use an extension cord to 

operate. All electrical wiring should comply with National 

Electrical Code and all other local codes. Contact a 

qualified electrician if you are not comfortable or  

familiar with electrical codes and/or installations.

10.

  FOR HOMES WITH A GAS OR OIL FURNACE 

LOCATED IN THE ATTIC: 

The ventilator MUST be 

wired with a switch or other interlocking device to 

prevent the furnace and ventilator from operating at the 

same time during the heating cycle. The switch or other 

interlocking device MUST disconnect the vent unit from 

both the electrical circuit power and the solar panel. We 

recommend that the switch (not provided) be installed 

by a qualified person in accordance with all applicable 

codes and standards.

CAUTION: FOR GENERAL VENTILATING USE ONLY.
THIS FAN HAS AN UNGUARDED IMPELLER.  

DO NOT USE IN LOCATIONS READILY ACCESSIBLE 

TO PEOPLE OR ANIMALS. DO NOT USE TO 

EXHAUST HAZARDOUS OR EXPLOSIVE  

MATERIALS OR VAPORS.
Important:

 Your solar panel configuration may differ from 

the one shown in the illustrations. The performance of all 

configurations is the same.

Tools Required

 

• Drill  

• Extension cord  

• 1/8” Drill bit  

• 7/16” Socket or adjustable wrench  

• Utility knife  

• Power saber or jigsaw and handsaw  

• Safety eyewear  

• Hard hat and other safety equipment  

• Fall restraint equipment  

• Galvanized roofing nails  

• Caulking gun  

• ASTM D4586 Type 1 or 2 Asphalt roofing cement  

   or ASTM C920 urethane sealant  

• Work gloves  

• Ladder  

• Claw hammer  

• Flat blade screwdriver  

• Phillips-Head screwdriver  

• Pencil or marker  

• Tape measure  

• 1/2” trade-size cable clamp connector  

• Type NM electrical cable  

• Wire nuts

V971390

Summary of Contents for Green Machine

Page 1: ...firm that there is sufficient electrical capacity on an existing circuit install a separate dedicated circuit DO NOT use an extension cord to operate All electrical wiring should comply with National Electrical Code and all other local codes Contact a qualified electrician if you are not comfortable or familiar with electrical codes and or installations 10 FOR HOMES WITH A GAS OR OIL FURNACE LOCAT...

Page 2: ...oll back and separate all shingles 7 178 mm from the top and sides of the cut out area Be sure that all roofing nails have been removed Using a saber saw jig saw or hand saw cut and remove all roof shingles and deck inside the 15 382 mm diameter circle Figure 3a Do not cut any rafters Test the final position by inserting the top half of the unit flashing under the rolled shingles Trim shingles as ...

Page 3: ...rethane sealant under the shingles to seal them to the roof C Attach top rail bracket Carefully lift up the shingles where the top rail mounting holes were previously marked Now align the panel frame between the installed L shaped wings Center the slots in the rails with the mounting holes on the wings Slide the top rails under the raised shingles and attach each rail to the roof deck with a provi...

Page 4: ...8 Wiring Remove Control Module cover by gently prying cover off of retention tabs on sides CAUTION Control board has sensitive electronic components Install trade size cable clasp connector not included in knockout and insert house power cable Connect house power wires as shown Figure 7 Adjust thermostat as desired from 60 F to 120 F 105 F recommended factory setting is 60 F Connect the male solar...

Page 5: ...menos 3 amperios de capacidad disponible Si no puede confirmar si hay suficiente potencia eléctrica en un circuito existente instale un circuito separado exclusivo NO UTILICE un cable extensor Todo cableado eléctrico deberá cumplir con el Código eléctrico nacional y con los demás códigos locales Contacte a un electricista calificado si usted no está familiarizado o no posee experiencia con códigos...

Page 6: ...stra en Figura 2b 3 Cortar abertura y verificar posición Restaure y separe todas las a tejas 7 178 mm de la parte superior y las partes laterales del área de corte Asegúrese de que se hayan quitado todos los clavos para techo Utilizando una sierra de vaivén una sierra caladora o una sierra de mano corte yquite todas las tejas del techo y de la cubierta ubicadas dentro del círculo de 15 382 mm de d...

Page 7: ...idadosamente y deslice cada grampa en L debajo de las tejas Alinee ambas grampas con la porción visible del esquema trazado Levante las tejas y coloque ambas grampas en L en la cubierta del techo con el tornillo para cubierta proporcionado Figura 5b Presione la teja en su lugar Aplique cemento para techos o sellador de uretano debajo de las tejas para sellarlas al techo C Colocar el soporte de la ...

Page 8: ...09 mm de longitud con tornillos de madera noincluidos utilizando lengüetas previamente perforadas en la parte lateral del Módulo de control 8 Cableado Quitar la cubierta del Módulo de control levantándola suavemente de las lengüetas de retención en los lados PRECAUCIÓN El tablero de control tiene componentes electrónicos frágiles Instalar el conector de abrazadera de no incluido en la abertura e i...

Page 9: ... au moins 3 ampères Si vous ne pouvez confirmer que le circuit actuel dispose d une puissance suffisante installez un circuit dédié distinct NE PAS utiliser de rallonge électrique pour faire fonctionner l appareil Tout le câblage électrique doit se conformer au National Electrical Code et à tout autre code local Faites appel à un électricien qualifié si vous n êtes pas à l aise avec les codes ou l...

Page 10: ...rdeaux à 178 mm 7 po du dessus et des côtés de la zone de découpe Assurez vous d avoir enlevé tous les clous pour toiture À l aide d une scie sauteuse ou d une scie à main coupez et enlevez tous les bardeaux et le platelage de toit à l intérieur du cercle de 382 mm 15 po Figure 3a Ne coupez pas les chevrons Testez la position finale en insérant la moitié supérieure du solin sous les bardeaux relev...

Page 11: ...fournies Figure 5b Appuyez sur le bardeau pour le remettre en place Appliquez de l enduit de toiture ou un scellant en uréthane sous les bardeaux pour les sceller au toit C Fixez le support du rail supérieur Soulevez délicatement les bardeaux aux endroits où les trous de montage ont été marqués précédemment Alignez ensuite le châssis du panneau entre les ailettes en L déjà installées Centrez les f...

Page 12: ...é perforées situées sur le côté du module de contrôle 8 Câblage Retirez le couvercle du module de contrôle en soulevant délicatement les pattes de retenue sur les côtés MISE EN GARDE Le tableau de contrôle renferme des composants électroniques fragiles Installez un connecteur Romex non compris dans la débouchure de po et insérez le câble d alimentation Branchez les fils du câble tel qu illustré Fi...

Reviews: