AFR200 Series, Product User Guide
This document is subject to change without notice.
Caution: None of GAC products are flight certified controls including this item
Copyright © 2010, Governors America Corp., All Rights Reserved
33
PUG4144 D
Typical Stoichiometric O
2
Sensors
7.3.1 Application Considerations
•
The oxygen sensors both have M18x1.5 thread as shown in the following figure. When selecting the
mating connection location ensure the fittings are correct.
Heated 12V Oxygen Sensor Dimensions – SOX102
Dimensions shown as in. [mm]
24V Oxygen Sensor Dimensions – SOX 103
Dimension
Value
Overall Length
1.2 in. [30.5mm]
Wire Quantity
2
Thread Size
M18 x 1.5
Length; Sealing Surface To End of Connector
12.60 in. [320mm]
Wire Length
13.80 in. [350.5mm]
•
For the primary oxygen sensor, the sensor should be located in the engine exhaust outlet as close to the
merge of all cylinders as possible but prior to the catalytic converter (if equipped).
•
In some cases on multiple bank engines (V-block engines) it’s possible to obtain acceptable
performance using exhaust gas from only a single bank although the preference if possible is at the
merge of both banks.
•
For the post-catalytic oxygen level sensor ensure the selected mounting location is mounted near the
catalytic converter in order to provide accurate data.
•
In turbo-charged applications the sensor must be installed no closer than 18 in. [457 mm] away after the
turbocharger outlet.
•
The SOX 102 sensor heater circuit is 12-14V capable only.
•
The SOX 102 sensor is provided with a 1/4” barbed fender plug in order to secure the electrical
connection point
.