2. INSTALLATION INSTRUCTIONS
The symbols used in the text are explained below:
WARNING This indication shows the possibility of causing death from electric shock.
WARNING This indication shows the possibility of causing death or serious injury.
CAUTION This indication shows the possibility of causing injury or damage to
properties only.
Symbol for useful information.
IMPORTANT:
Wiring procedures and connections shall
be in accordance with the national and local codes
having jurisdiction.
• The installation must be carried out in accordance
with the current local electrical regulations.
Any installation or reinstallation has to be carried
out by an experienced technician.
• Neither the connecting cable nor any other object
must come into contact with the hot unit.
• Please check that the voltage in the rating label fits
the power supply. The nominal charging period of this
heater is indicated in the rating label. This appliance
must be grounded.
• The appliance should not be installed just below an
electrical socket.
• The appliance must be installed in such a way that
it is impossible for anyone using a bath or shower,
to touch the controls.
• If during any installation the thermal insulation shows
any sign of damage, it must be replaced.
• This heater should be switched off at the circuit
breaker before any repair work is carried out.
This should also be done during times of the year
when heat is not required.
• This appliance is only for permanent connection to
a fix installation. The supply circuit to the heater must
incorporate a double pole isolating switch having a
contact separation of at least 3 mm.
• After installation a survey of the first charging cycle
should be carried out to ensure that the main input
thermostat switches off. Ventilate the room during
this first cycle.
• To maintain stability, it is essential that the heater is
placed on a level surface and care should be taken
to avoid irregular surfaces, such as may result from
carpets or tiled surrounds partially protruding under
the heater.
• The presence of air particles of smoke, dust and
other pollutants could, in time, discolour the walls
and surfaces around the heater.
• Incorrect time settings, erroneous programming of the
reduced rate time and too high temperature settings
may result in a high cost of your electricity bill.
In order to achieve a correct installation of this device,
follow these steps:
1. Choose the right location to install ECOMBI SSH.
The minimum clearances must be respected from
the appliance to any combustible material such as
furniture or curtains.
To reduce the risk of fire,
do not store or use gasoline or other flammable
vapours and liquids in the vicinity of the heater.
2. Open the carton at the indicated side and install the
supporting feet without removing the heater.
!
!
!