![background image](http://html1.mh-extra.com/html/gabarron/cpe/cpe_installation-instructions-and-user-manual_555621007.webp)
- 7 -
OVERVIEW
•
Large capacity boiler (40 litres).
•
Electrical panel incorporated.
•
Three heat outputs.
Input
kcal/h
Voltage
Pipe size
Weight
24 kW
20.640
N~
1 1/4"
76 kg
27 kW
23.220
N~
1 1/4"
76 kg
30 kW
25.800
N~
1 1/4"
76 kg
33 kW
28.380
N~
1 1/4"
76 kg
36 kW
30.960
N~
1 1/4"
76 kg
39 kW
33.540
N~
1 1/4"
76 kg
42 kW
36.120
N~
1 1/4"
76 kg
45 kW
38.700
N~
1 1/4"
76 kg
48 kW
41.280
N~
1 1/4"
76 kg
51 kW
43.860
N~
1 1/4"
76 kg
54 kW
46.440
N~
1 1/4"
76 kg
Space heating energy efficiency class
D
Space heating energy efficiency (
η
s)
%
37
Sound power level (LWA)
dB
36
2. GETTING STARTED
- Check that all drains are closed.
- Open the filling tap until the hydrometer (7) shows 1 kg/cm
2
.
- Open and close all the purging valves as soon as the water flows.
- Set the thermostat control (11) to minimum and be sure that the pump works normally.
- Open the purging valves again if needed.
- Open the filling tap until the hydrometer (7) shows 1.5 kg/cm
2
.
- Connect the main switch (1), the thermostat control and the switch (3) to start the heater.
A: Output
B: Input
Summary of Contents for CPE
Page 11: ... 11 NOTAS NOTES ...