5. Operation
The nominal load is only reached under the nominal voltage. Falling under the nominal voltage
reduces the nominal load.
Operation with a "dead man’s push button"
During operation with a "dead man’s switch", current feeding must take place until the end of the
closing process.
6. Maintenance
Under no circumstances should alkaline or acidic solutions be used for cleaning purposes.
The following tests need to be carried out after every 1000 opening-cycles:
Inspect whether all screws are tightly fastened and retighten them if necessary.
Visually inspect all components for any signs of damage or wearing out, and replace these if
necessary.
Ensure that the limiting switches are set correctly.
At least once a year, conduct a visual inspection of the power cable. It may not be damaged, nor may
any signs of wearing out or faults exist.
Discontinue the current and power supply of the motor during the cleaning and maintenance
process.
Apply grease to the hardware at the designated points using acid-free grease.
Rectifying disturbances
In case the drive stops running, please have a professional electrician examine the electricity supply.
If the disturbances cannot be rectifi ed by qualifi ed professionals, replace the faulty drive and have
the manufacturer repair it.
7. Further
documents
Installation drawing fanlight opener VENTUS F 200
0-43700
Installation drawing fanlight opener VENTUS F 200 with electric drive ELTRAL S
0-48801
Installation drawing fanlight opener VENTUS F 200 Top-Hung sash
0-43818
Summary of Contents for ELTRAL S 230
Page 18: ...18 ELTRAL S 230 07 2019 G36582 Designed in Germany ...
Page 19: ...19 ...