13
3.2 Electric
Caution
Only operate the drive with 230 V ~.
The electric installation may only be carried out by professional electricians while following the
safety regulations. The connection cables may not be put under the strain of twisting, crushing or
shearing off .
In case it has not yet been done, remove the safety screw M3 on the frontal plastic cover on the side
of the electric connection. Remove the plastic covers by pulling them off in an upward direction.
Connect the drive according to the connection diagram. The detailed connection diagram is located
at the end of this manual. It is crucial that the connection cable is fastened using the designated
strain relief!
In case of disconnecting the ground wire from the cover during mounting the drive or in case
of separate delivery of the cover and the drive, the ground wire must be connected electrically
conducting. It must be tested and recorded that the electrical resistance between the cover and
terminal 5 (PE) is max. 1 Ω according DIN VDE 0100-600. According to the place of installation,
further country-specifi c regulations must be observed!
The drive is suitable for interior mounting and should principally operate with a rain-sensor.
After assembly, be sure to place the front and rear covers back onto the drive. It is essential that you
screw the safety screw M3 back into the plastic cover on the side of the electric connection. Do this
until the screw is even with the surface of the cover.
4. Initial
Operation
Before putting the drive into operation for the fi rst time, please verify whether the drive has been
properly fi xed onto the respective object (please see Assembly mechanical and electric) and whether
the electric connection was carried out in accordance with the requirements listed above.
Pay attention to the electric supply cables and inspect these for potential damage. If necessary, have
a professional electrician exchange the supply cables.
If the requirements listed above have been met, the two limiting switches may be adjusted. The
limiting switches are adjusted by turning the frontal setting screws using a screwdriver (refer to
connection diagram for turning direction). The limiting switches must be adjusted in such a way that
the window mechanics and the drive are not strained to block.
In the delivery condition, the limit switches are set to fi t the fanlight opener F 200. If necessary, a
fi ne adjust is required.
The drive has an internal thermal switch. When reaching a high motor temperature, the drive
switches off . This is a overload protection for the 230 V ~ motor, which does not exclude mechanical
damages.
During the stroke adjustment through the limiting switches, make sure that the respective limiting
switch has switched off correctly. If this is the case, the control lamp will switch off . The control lamp
may not switch on in the fi nal positions!
Before commencing with the initial operation, verify whether the two limiting switches have been
adjusted correctly in order to avoid damage being caused to the fi tting or window construction!
Once both limiting switches have been adjusted, you must conduct a fi rst trial run.