![G-U ELTRAL OA Installation And Operating Instructions Manual Download Page 24](http://html.mh-extra.com/html/g-u/eltral-oa/eltral-oa_installation-and-operating-instructions-manual_555169024.webp)
24
Square spindle drive for window handles
Installation and operating instructions
ELTRAL OA
7
Wiring and adjustment
DANGER
ATTENTION
Risk of damaging the motor beyond repair
The motor requires a 24 V DC connection. Other voltages will damage it
beyond repair.
Connect the motor accordingly.
Do not lay the motor connection cable together with a mains cable.
Never connect 24 V DC actuators to a 230 V mains.
Danger of life !
Lay low-voltage lines separately from power lines.
Attention!
The unattached opening drive must be connected in order to adjust the
square-spindle drive.
Switch poles if the running direction of the opening drive is reversed.
7.1 Connecting opening drives (e.g., K25, K60)
OA
34
on off
=
on
for connection
of OA, cf. p. 24
Maximally permitted current consumption de-
pends on cable the length ! (refer to page 22)
white
white
black
Brown
blue
white
blue brown
blue brown
Synchro
operation requires
programmed
drives.
For tandem operation
connect white wire !
Drive 1
Drive 2
required
adjustment: