12000W/13000W Dual Fuel Generator
IF THERE IS A STRONG SMELL OF PROPANE WHILE OPERATING THE GENERATOR CLOSE
THE VALVE ON THE PROPANE TANK IMMEDIATELY. ONCE THE PROPANE IS OFF, USE
SOAPY WATER TO CHECK FOR LEAKS ON THE HOSE AND CONNECTIONS ON THE TANK
VALVE AND THE GENERATOR. DO NOT SMOKE OR LIGHT A CIGARETTE OR CHECK FOR
LEAKS USING ANY OPEN FLAME SOURCE SUCH AS A MATCH OR LIGHTER. IF A LEAK IS
FOUND CONTACT QUALIFIED TECHNICIAN TO INSPECT AND REPAIR THE LPG SYSTEM BEFORE
USING THE GENERATOR.
C
onnecting LPG Tank
⚫
Make sure propane tank valve is in the off position.
⚫
Make sure the fuel selector switch on the generator control
panel is pointing downward to “Propane”.(pic 1)
⚫
Remove the plastic cover on the generator propane inlet valve.(pic2)
⚫
Using your fingers tighten the LPG hose (included) end below to the generator propane inlet.
DO NOT OVER-TIGHTEN 35-88 Ib-in maximum.(pic3)
⚫
Attach the other end of the hose to a tank of LPG/Propane and hand tighten.(pic4)
Pic 1
Pic 2
Pic3
Pic4
WARNING
DO NOT START GENERATOR IF YOU SMELL PROPANE. THIS MAY RESULT IN EXPLOSION HAZARD.
DO NOT USE PROVIDED LPG HOSE FOR ANY OTHER APPLIANCES. ALWAYS TURN OFF THE
PROPANE TANK AND DISCONNECT LPG HOSE WHEN NOT IN USE.
LPG IS UNDER PRESSURE AND CAN CAUSE A FIRE OR EXPLOSION IF IGNITED.