ELECTRIC TURBO OVEN
FTE 300-240-150-120
Mal use of the equipment;
ATTENTION! Never clean glass pane of the door when oven is still warm because
that can cause it to break.
1- Oven doesn't turn on:
Perform external cleaning of the oven with mild soap and clean water. Never use products
that may damage painting of the oven such as solvents, chemical products, steel wool, etc.
Check if emergency switch key is unlocked;
Check fuse;
Check if oven is connected to power supply;
Check if there is electric energy being supplied.
CLEANING THE OVEN
TROUBLESHOOTING AND POSSIBLE SOLUTIONS
2- Steam doesn't work:
3- Turbine doesn't turn on:
4- Lamp doesn't turn on:
Check if water valve is open;
Check if door is completely shut;
Check if control switch key has been activated by sound signal (1 beep);
Check if there is water being supplied;
With door open press micro switch key for 5 seconds; if turbine does not turn on,
contact G. Paniz Authorized Service.
Replace bulbs;
*** Should any of the problems persist, please contact one of G. Paniz authorized service offices.
WARRANTY TERM
All parts that make up the machine, except for the motor are covered by this warranty
term for a 6-month period, regarding any manufacturing defects.
This warranty term will be void in the following situations:
Should the equipment be opened or maintenance be carried out by non-authorized
services;
Material is sent to maintenance without previously consulting manufacturer or service;
Purchase invoice is not presented at dealer.
Attention:
Even though G. Paniz doe s not take any responsibility on electric motors,
these have a 1-year warranty period granted by their manufacturers; from the date invoice bill
is issued. In order to be entitled to this warranty, all you need is to present your purchase
invoice to the authorized service indicated by the manufacturer of the motor and do not break
any warranty conditions imposed by the manufacturer.
ELECTRIC SUPPLY
Model
FTE 120
FTE 150
FTE 240
FTE 300
Triphase 220v
1 cv
18 Kw
30 A
Triphase 380v
1 cv
15 Kw
15 A
Triphase 220v
1 cv
15 Kw
25 A
Triphase 380v
¼ cv
9 Kw
15 A
Triphase 220v
¼ cv
9 Kw
15 A
Triphase 380v
¼ cv
9 Kw
15 A
Triphase 220v
¼ cv
9 Kw
15 A
Triphase 380v
1 cv
18 Kw
25 A
Tension
Motor
Power
Resistance
Power
Protection Circuit Breaker
Recommended (3-pole)
ELECTRIC TURBO OVEN
FTE 300-240-150-120
Model
Dimensions:
FTE 120
FTE 150
FTE 240
FTE 300
1300
1300
1470
1470
580
660
1160
1000
1530
1610
1700
1770
820
820
860
860
980
980
940
940
Width
including
Switchboard
( mm )
Width not
including
Switchboard
( mm ) )
Width
including
Base
( mm )
Width not
including
Base
( mm )
Depth
( mm )
Voltage of the oven:
check whether voltage of the equipment is the same of your
electric supply.
Wall socket:
socket where oven is to be connected should be a monophase or 3-phase
fix plug, dimensioned for the nomina l current of the protection circuit ( thermal-electrical
breaker), allowing full exemption of plug pins, without any clearances, so that sharp live parts
cannot be touched by human hand.
Socket wiring
: they should be rigorously in accordance with their respective compensations
as described in the Brazilian Standard NBR 5410 - ABNT ( Associação Brasileira de Normas
Técnicas - the Brazilian Association for Technical Standards ). Should you have any doubts
consult a specialized electrician.
Protection:
: at the circuit where oven is to be plugged to, there must be a thermal-electrical
circuit breaker as per the table below.
Ground wiring or Earth wire:
ground wire of your oven should be connected to an effective
earth cable, thus preventing from personal risks. Connection to a ground wire is necessary
under any voltage, and should not be connected to the neutral wire of the power supply, neither
to the hydraulic, gas or electrical piping, nor the faucets, etc. For a perfect ground wiring,
observe instructions under the Brazilian Standard NBR 5410 - ABNT, “Grounding Wire”.
It is the customer's responsibility if it is not possible to turn equipment on.
A CONNECTION TO A GROUND WIRING SYSTEM IS MANDATORY.
23
16
Summary of Contents for FTE 120
Page 2: ......