16
PLEASE NOTE:
If using for a caravan, motor home
or boat etc refer to the
manufacturers manual regarding
connection of a generator.
Do
NOT
connect into a house
ring main circuit.
If the generator is not to be used or is to be stored for
more than one month the following storage procedure
should be carried out. Drain all the fuel from the fuel
tank and the carburettor, ensure that all the fuel has
been removed. Remove the spark plug and pour
approximately one tablespoon full of clean engine oil
into the spark plug hole. With the ignition turned OFF
gently pull on the recoil starter cord several times. Re-
fit the spark plug and continue to pull the recoil starter
cord until the piston is on the compression stroke
(when resistance is felt) then stop puling.
Store the generator in a dry well ventilated place
under a cover to prevent any dust or debris from
accumulating on the generator.
DRAINING ThE CARBURETOR
1.
Turn off fuel valve, make sure fuel is drained
and the tank is empty. Residual gasoline left
over a long time will cause difficulty when next
starting the engine.
2.
Position an approved fuel container under the
carburetor drain screw to catch fuel; loosen the
screw. (Fig.21). Allow fuel to drain completely
into container.
3.
Retighten drain screw.
4.
After draining the fuel tank and carburetor, start
the engine and allow it to run until the unit runs
out of fuel. Consult hazardous waste management
guidelines in your area for the proper way to
dispose of fuel.
GENERAL INSPECTION & STORAGE
Regularly check that all the fixing screws are tight.
They may vibrate loose over time.
STORAGE
If the generator is not to be used or is to be stored for
more than one month the following storage procedure
should be carried out. Drain all the fuel from the fuel
tank and the carburettor, ensure that all the fuel has
been removed. Remove the spark plug and pour
approximately one tablespoon full of clean engine oil
into the spark plug hole. With the ignition turned OFF
gently pull on the recoil starter cord several times. Re-
fit the spark plug and continue to pull the recoil starter
cord until the piston is on the compression stroke
(when resistance is felt) then stop pulling.
Store the generator in a dry well ventilated place
under a cover to prevent any dust or debris from
accumulating on the generator.
Summary of Contents for 502313382
Page 2: ...1 1 13 7 5 2 8 9 4 3 6 12 11 10 14 2...
Page 3: ...1A 15 20 16 17 18 19 3...
Page 4: ...4 2 Fuel Filter Tank Cap 4 3 5 6 1 2 3 4 5 6 8 7 9 10...
Page 5: ...5 11 13 8 10 12 14 7 9...
Page 6: ...6 21 16 15 17 19 20 18...
Page 112: ...112...
Page 113: ...113...