FWE R-AS-10 Operating Instructions Manual Download Page 4

TRANSPORTING & UNIT FEATURES

7

FWE 

REFRIGERATED "AIRSCREEN" SERIES

6

 

FWE Operating Instructions | Refrigerated "AirScreen" Series

INSTALLATION

FWE 

REFRIGERATED "AIRSCREEN" SERIES

TRANSPORTING

1.  WARNING:

 Do not attempt to move the AirScreen Refrigerator until the unit is turned 

off, the power cord is unplugged and out of the way, or secured around the rear handle. 

2.  Door must be securely closed and all caster locks released. 

3.  Maneuver the unit by grasping the handles on the sides or rear.  

4.  CAUTION:

 

The unit is designed for internal use and not designed for outdoor all-

terrain transport.  

5.  CAUTION:

 The heavy compressor assembly is located 

at the bottom of the unit and lowers its center of gravity. 

Moving the product loaded with product can change the 

center of gravity making the unit top heavy losing some 

stability. Be extra cautious when approaching uneven 

flooring and when going over door thresholds, drains and 

grates.

UNIT FEATURES

Temperature setting: 

Your units operating temperature is preset to 38°F (3.3°C) with an operating temperature range 

of 33°F to 40°F (.5°C to 4.4°C).

Full Swing Door with Magnetic (hold open) Catch:

Door can open flat against the cabinet side and is secured in place by a magnetic catch. 

Closed door is secured magnetically thus removing the need for a cumbersome door latch. 

Tray Slides:

Ten (10) pairs of removable stainless steel tray slides are provided.  Tray slides are spaced at 

4 ½” and each space can accommodate one (1) 18”x26” standard sheet pan.

Side Grips and Rear Handles:

For ease of mobility stainless steel recessed hand grips are provided on the left and right sides 

and a 1” welded tubular push/pull handle is attached to the rear of the cabinet.

Casters: 

6” diameter polyurethane casters attached to 10 gauge stainless steel corner reinforcement 

plates are standard. Front casters have foot actuated locks.

INSTALLATION

Location: 

The proper location and assembly of your FWE AirScreen is extremely important for proper 

performance.  Carefully follow the guidelines listed below: 

1.  Install unit level. 

 

This is important for the health of the refrigeration system and efficient draining of the defrost 

water. Improper draining of evaporator water can cause loss in performance and require additional 

defrosting. 

2.  Install unit away from hot cooking equipment or other sources of heat. 

 

Being near heat sources can increase the ambient temperature around the unit making it work 

harder, lose efficiency and shorten effective open door time. 

3.  Install unit away from appliances that give off steam or moisture. 

 

Increased room humidity speeds up the formation of frost on the evaporator coil shortening the 

effective open door time. 

4.  Install the unit away from room ventilation ducts and not under ventilation hoods. 

 

Moving air from ventilation ducts or hoods can disturb the air flow around the unit which can cause 

poor open door performance. Especially avoid locations where there is airflow directed at the front 

of the unit that can push air and humidity into the cabinet when the door is open. Also avoid drafty 

locations like near frequently opened doors. 

5.  Install the unit with a minimum of 6” from the back of the unit to a wall or other obstruction.

 

Proper clearance is required for good airflow around the condenser unit for efficient operation. 

6.  Install unit so the doors can be opened a minimum of 90 degrees:

 

The door is designed to swing and latch to the side of the unit. 

7.  Install the tray slides:

 

Tray slides have tabs formed into them. Slide the tabs into the square holes on the side of the 

cabinet and push down to seat. The slides can be installed level or can be mounted at a slight slope 

forward to help product slide forward on the trays. 

8.  Side air tunnels:

 

Side tunnels inside the unit must be installed tightly against the inside walls of the cabinet. This is 

important for proper cold air flow across the product on the trays. 

9.  Install unit away from areas where there may be frequent standing water.

 

10.  Install unit in an area that is conducive to safe and proper use.

 

Summary of Contents for R-AS-10

Page 1: ...REFRIGERATED AIRSCREEN SERIES OPERATING INSTRUCTIONS ASU R AS SERIES MODELS Caution Read the instructions before using the machine...

Page 2: ...tration online www fwe com warranty Scan the QR code to the right Warranty registration must be submitted within 30 days of initial delivery to be valid 4 Make sure all operators are familiar with the...

Page 3: ...livery in good order when the shipment was accepted 2 All units are factory tested for performance then carefully packaged and certified free from defects when shipped 3 Inspect the packaging for exte...

Page 4: ...Screen is extremely important for proper performance Carefully follow the guidelines listed below 1 Install unit level This is important for the health of the refrigeration system and efficient draini...

Page 5: ...Repeat the steps if necessary to get the desired temperature unit On Indicator Light Indicates the unit is turned on Cycle Indicator Light Lights when the refrigeration system is running unit is cool...

Page 6: ...s soon as possible gives more time for the unit to cool back down between open door sessions CONTINUES ON NEXT PAGE OPERATION Closed door operation When the door is closed it operates like a highly ef...

Page 7: ...be visible and should be considered a normal operating condition 5 Defrost cycles take around 15 minutes However it is advisable to allow a minimum of 45 minutes for a defrost cycle This allows time f...

Page 8: ...te corrosion of the stainless steel CONTINUED ON NEXT PAGE DEFROST CONTINUED 6 Defrost is not canceled when you open the door If possible let the defrost cycle finish and allow the compressor to come...

Page 9: ...the ingredients of cleaning solutions or disinfectants used as they may contain chlorinated solvents Always read the label of the cleaning solutions Check warnings about use on stainless steel produc...

Page 10: ...ssue or other internal issue Technician required 2 Closed door cabinet temperature too high unit running A Control Setting is too high Set a lower temperature on the control B Product temperature very...

Page 11: ...D AIRSCREEN SERIES 20 FWE Operating Instructions Refrigerated AirScreen Series WIRING DIAGRAM FWEREFRIGERATED AIRSCREEN SERIES WIRING DIAGRAMS FOR ASU 10 WIRING DIAGRAMS FOR R AS 10 R AS 10 220V R AS...

Page 12: ...g any repairs If service is required during overtime periods the difference between overtime and standard labor rates shall be paid by the purchaser Seller does not assume any responsibility for any c...

Page 13: ...rrors subject to correction All specifications subject to change without notice Printed in USA Food Warming Equipment Company Inc 5599 Highway 31W Portland TN 37148 3 IF YOU CAN DREAM IT WE CAN BUILD...

Reviews: