TABLE OF CONTENTS & GENERAL INFORMATION

FWE 

REFRIGERATED "AIRSCREEN" SERIES

IN THE EVENT OF ACCIDENT OR 

BREAKDOWN

 - UNPLUG UNIT.

INTRODUCTION 

 

Congratulations and thank you for purchasing a 

FWE AirScreen Refrigerator.

The unit has the exclusive “Food Sentry” AirScreen 

control that offers the ultimate in performance and is designed to operate continuously as a 

highly efficient “standard” closed door refrigerator or as an “AirScreen”. 

*

With the door open the unit is capable of maintaining 

40°F (4.4°C)

 temperature 

or below

 for 

minimum

 

45 minutes

 and a 

maximum

 of 

120 minutes (R-AS-10 Model)

 / 

4 hours (ASU-10 

Model)

 

depending on conditions

IMPORTANT THINGS TO DO BEFORE USING YOUR FWE AIRSCREEN:

1.  Carefully uncrate your unit and check it for damage following the procedures outlined in 

this manual. 

                                              

2.  Read this installation and operating manual carefully for proper installation and use of 

your unit. 

3.  Submit your Warranty & Manufacturer Registration online 

(www.fwe.com/warranty). Scan the QR code to the right. 

Warranty registration must be submitted within 30 days of 

initial delivery to be valid.

 

4.  Make sure all operators are familiar with the proper and safe 

operation of this equipment as described in this manual.

ASU-10

Model Shown

TABLE OF CONTENTS

Table of Contents & General Information 

Page 2

I. Introduction 

   Page 

3

II. 

Delivery Inspection & Unpacking   

Page 4

III. 

Electrical Requirements   

 

Page 5

IV. 

Installation 

   Page 

6

V. 

Transporting 

   Page 

7

VI. 

Unit 

Features 

   Page 

7

VII. 

Electronic Controls 

 

 

Page 8 - 9

VIII. 

Operation    Page 

10

IX. 

Performance 

   Page 

11-12

X. 

Defrost 

    Page 

12-14

XII. 

General Cleaning and Maintenance   

Page 14-17

XIII. 

Service Information 

 

 

Page 17

XIV. 

Troubleshooting Guide 

 

 

Page 18-19

XV. 

Wiring 

Diagram 

   Page 

20-21

XVI. 

Warranty 

    Page 

22

XVII. 

Warranty Registration & Service Record 

Page 23

GENERAL INFORMATION

A schedule should be put in place for inspections and preventative maintenance. 

New users should be properly trained in the use of this equipment.

No special protective equipment is required to operate this unit. 

*

FOR SERVICE INQUIRIES PLEASE CALL

FWE SERVICE • 800-222-4393

Door Open duration is based on a room ambient

temperature of 75°F (24°C) and 45% relative humidity.

Summary of Contents for R-AS-10

Page 1: ...REFRIGERATED AIRSCREEN SERIES OPERATING INSTRUCTIONS ASU R AS SERIES MODELS Caution Read the instructions before using the machine...

Page 2: ...tration online www fwe com warranty Scan the QR code to the right Warranty registration must be submitted within 30 days of initial delivery to be valid 4 Make sure all operators are familiar with the...

Page 3: ...livery in good order when the shipment was accepted 2 All units are factory tested for performance then carefully packaged and certified free from defects when shipped 3 Inspect the packaging for exte...

Page 4: ...Screen is extremely important for proper performance Carefully follow the guidelines listed below 1 Install unit level This is important for the health of the refrigeration system and efficient draini...

Page 5: ...Repeat the steps if necessary to get the desired temperature unit On Indicator Light Indicates the unit is turned on Cycle Indicator Light Lights when the refrigeration system is running unit is cool...

Page 6: ...s soon as possible gives more time for the unit to cool back down between open door sessions CONTINUES ON NEXT PAGE OPERATION Closed door operation When the door is closed it operates like a highly ef...

Page 7: ...be visible and should be considered a normal operating condition 5 Defrost cycles take around 15 minutes However it is advisable to allow a minimum of 45 minutes for a defrost cycle This allows time f...

Page 8: ...te corrosion of the stainless steel CONTINUED ON NEXT PAGE DEFROST CONTINUED 6 Defrost is not canceled when you open the door If possible let the defrost cycle finish and allow the compressor to come...

Page 9: ...the ingredients of cleaning solutions or disinfectants used as they may contain chlorinated solvents Always read the label of the cleaning solutions Check warnings about use on stainless steel produc...

Page 10: ...ssue or other internal issue Technician required 2 Closed door cabinet temperature too high unit running A Control Setting is too high Set a lower temperature on the control B Product temperature very...

Page 11: ...D AIRSCREEN SERIES 20 FWE Operating Instructions Refrigerated AirScreen Series WIRING DIAGRAM FWEREFRIGERATED AIRSCREEN SERIES WIRING DIAGRAMS FOR ASU 10 WIRING DIAGRAMS FOR R AS 10 R AS 10 220V R AS...

Page 12: ...g any repairs If service is required during overtime periods the difference between overtime and standard labor rates shall be paid by the purchaser Seller does not assume any responsibility for any c...

Page 13: ...rrors subject to correction All specifications subject to change without notice Printed in USA Food Warming Equipment Company Inc 5599 Highway 31W Portland TN 37148 3 IF YOU CAN DREAM IT WE CAN BUILD...

Reviews: