1) PLUG CABINET INTO OUTLET, making sure it is a properly
grounded power receptacle. Press ON-OFF rocker switch to "ON"
position.
2) FILL THE HUMIDIFIER PAN with HOT water. This pan is removable
for ease in cleaning. It is not necessary to remove the pan to fill it.
3) PRE-HEAT THE CABINET by turning the rocker switch to the "ON"
position, and setting the HEAT control to 100°F. Allow approximately
20-30 minutes of pre-heat time. The door should be kept tightly closed
during this procedure, to obtain the optimum proofing environment.
4) SET PROOF CONTROL to desired setting. For uniform raised
dough results, suggested setting are No. 5 for 1-7 dial face or “P”
on
Low-Med-High dial face
. At these settings, the proofing system
maintains an optimum 95°- 95% heat / humidity balance.
Below are examples of results at several temperature / proof setting
combinations. As a rule of thumb,
the higher the heat setting, the lower
the humidity
, since higher temperatures will cause more rapid evapora-
tion of the moisture.
EXAMPLE: If heat setting is at
100°F
, and proof setting is at #5 or “P”,
it should result in
96% relative humidity
in the interior of the cabinet.
EXAMPLE: If heat setting is at
140°F
, and proof setting is at #5 or “P”,
it should result in
90% relative humidity
in the interior of the cabinet.
EXAMPLE: If heat setting is at
152°F
, and proof setting is at #5 or “P”,
it should result in
75% relative humidity
in the interior of the cabinet.
NOTE: As with all Proofing cabinets, your results may vary, depending
on cabinet model (size of interior), room temperature and conditions,
pre-heat time, temperature of product going into cabinet, etc... It is
suggested that you experiment with various products at various settings
to achieve optimum, uniform results for your particular application.
5) LOAD THE CABINET with your product as quickly as possible.
To maintain the best proofing conditions, the door should be tightly
closed when not loading the cabinet, and remain closed for the
duration of the proof time necessary for your product.
6
GENERAL OPERATING INSTRUCTIONS
PROOF MODE