1)  PLUG CABINET INTO OUTLET, making sure it is a properly  
grounded power receptacle. Press ON-OFF rocker switch to "ON" 
position.

2)  FILL THE HUMIDIFIER PAN with HOT water. This pan is removable
for ease in cleaning. It is not necessary to remove the pan to fill it.

3)  PRE-HEAT THE CABINET by turning the rocker switch to the "ON"
position, and setting the HEAT control to 100°F. Allow approximately 
20-30 minutes of pre-heat time. The door should be kept tightly closed 
during this procedure, to obtain the optimum proofing environment.

4)  SET PROOF CONTROL to desired setting. For uniform raised 
dough results, suggested setting are No. 5 for 1-7 dial face or  “P”
on 

Low-Med-High dial face

. At these settings, the proofing system 

maintains an optimum 95°- 95% heat / humidity balance.
Below are examples of results at several temperature / proof setting 
combinations. As a rule of thumb, 

the higher the heat setting, the lower

the humidity

, since higher temperatures will cause more rapid evapora-

tion of the moisture.

EXAMPLE: If heat setting is at 

100°F

, and proof setting is at #5 or “P”,

it should result in 

96% relative humidity 

in the interior of the cabinet.

EXAMPLE: If heat setting is at 

140°F

, and proof setting is at #5 or “P”,

it should result in 

90% relative humidity 

in the interior of the cabinet.

EXAMPLE: If heat setting is at 

152°F

, and proof setting is at #5 or “P”,

it should result in 

75% relative humidity

in the interior of the cabinet.

NOTE: As with all Proofing cabinets, your results may vary, depending 
on cabinet model (size of interior), room temperature and conditions, 
pre-heat time, temperature of product going into cabinet, etc... It is 
suggested that you experiment with various products at various settings
to achieve optimum, uniform results for your particular application.

5)  LOAD THE CABINET with your product as quickly as possible.
To maintain the best proofing conditions, the door should be tightly 
closed when not loading the cabinet, and remain closed for the 
duration of the proof time necessary for your product.

6

GENERAL OPERATING INSTRUCTIONS

PROOF MODE

Summary of Contents for ETC-PH Series

Page 1: ...ETC PH Series Enclosed Transport Cabinet with Removable Proofer Heater Module OPERATING INSTRUCTIONS REMOVABLE PROOFER HEATER...

Page 2: ...e most efficient service Please take a moment to read through this booklet of important information pertaining to your cabinet By following a routine of proper use and care described on the following...

Page 3: ...PROOFER HEATER 3 Thermometer Proofer Humidity Control Cord Winding Bracket With removable water pan secured by strap that doubles as handle Main Power On Off Switch Heat Control Can be used with or w...

Page 4: ...FROM THE CORD PLUG WARNING ONLY A QUALIFIED ELECTRICIAN SHOULD ATTEMPT TO REPAIR OR REPLACE ELECTRICAL COMPONENTS OR WIRING BE SURE THAT MODEL IS UNPLUGGED FROM ELECTRICAL SOURCE BEFORE REMOVING CONT...

Page 5: ...al temperature of the cabinet 5 CLEANING FWE ETC CABINET WITH REMOVABLE PROOFER HEATER INSTALLATION AND CARE Keep your cabinet clean by simply wiping the interior and exterior as needed with a damp cl...

Page 6: ...igher temperatures will cause more rapid evapora tion of the moisture EXAMPLE If heat setting is at 100 F and proof setting is at 5 or P it should result in 96 relative humidity in the interior of the...

Page 7: ...lding temperature of 150 160 F should be adequate By keeping the water pan filled and the HEAT control set at 150 F a normal 40 humidity level will be achieved 4 PRE HEAT CABINET FOR 20 30 MINUTES AVO...

Page 8: ...th small blade screwdriver by turning COUNTER CLOCKWISE 1 4 turn raises temperature approximately 10 F DO NOT REMOVE SET SCREW 3A Plug unit into properly grounded electrical outlet 3B Adjust thermosta...

Page 9: ...9 FWE ETC CABINET WITH REMOVABLE PROOFER HEATER WIRING DIAGRAM 120v 220v...

Page 10: ...ometer T METER H1 Extension cord 10 ft 115v CRDSET 10 115 Cord winding bracket BRK CRD 1 Heating element EL1250 115HT Proofer element EL350 120 STP 12 Blower motor BLWR REV 115 230 On Off switch SWH R...

Page 11: ...eriod of one 1 year except for equipment used in a Correctional Environment Facilities which is warranted for a period of six 6 months This warranty is for normal usage and does not apply to any produ...