00114770.DOCX, Version 1.1
25/32
Connection to the mains
The device uses an auto-range power supply that accepts input voltages between 100 und 240 volts.
1 Connect the device via the enclosed mains cable to a grounded mains socket. Thus the unit is switched
on.
2 To switch off the unit, disconnect the power plug.
3 Do not connect the unit to the mains voltage via a dimmer. For a more convenient operation, use a mains
outlet which is switchable.
Power supply of further devices
The jack POWER OUT allows for power supply of further devices. To interconnect several devices, connect
the jack POWER OUT to the input POWER IN of the next unit until all units are connected. Matching power
cables with P-Con plugs are available as accessories. In this manner, up to 8 devices can be linked at
230/240 input voltage and up to 4 devices at 110/115 input voltage.
OPERATION
After connecting the device to the mains it is ready for operation. The display indicates the last operating
mode. The operating modes can be selected by means of the display and the control buttons. All settings
remain stored even if the device is disconnected from the mains. The device can be operated in stand-alone
mode via the control board or in DMX-controlled mode via any commercial DMX controller.
Stand-alone mode
In the stand-alone mode, the device can be used without controller. Disconnect the device from the
controller.
Operating buttons
MODE
Selects the operating mode or returns to the initial screen.
ENTER
Activates a value to be modified or saves a value when modifying.
UP
Selects the next menu item or increases values when modifying.
DOWN
Selects the previous menu item or decreases values when modifying.