background image

21

DISPLAY

 

FITTING

The mechanism should be fully extended 

before the screen can be fitted.

1

Press the ‘OUT’ button on the remote 

and wait for the SPS to fully extend.

2

Press ‘B’ on the IR remote repeatedly 

to pulse the mechanism fully out into 

its service mode.

3

Manually pull the mechanism out further 

so that the screen uprights can be bolted 

onto the frame.

4

Attach the screen uprights to the 

display and offer it to the mechanism.

5

Make final adjustments to the display 

by altering the height that the display 

is fixed to the upright slots, or 

adjusting the SA/SAH top bolt heads 

on the screen mount plate..

6

Return the mechanism from 

service mode by pressing ‘A’ 

repeatedly on the IR remote. 

Once the mechanism cannot 

pulse any further, wait 2 

seconds and the mechanism 

will return to user mode.

If further adjustments need to be 

made. Remove and reposition the 

display on the mounting uprights.

7

Summary of Contents for SPS & SA

Page 1: ...ISSUE 014 SLIDING PANEL SYSTEM SCREEN ADVANCE SCREEN ADVANCE HEAVY SPS SA SAH INSTALLATION INSTRUCTIONS...

Page 2: ......

Page 3: ...been specifically designed to do so 4 Protect any cables or cords being used near this bracket from being walked on or pinched to prevent damage and risk of injury 5 Use this product only for its int...

Page 4: ...mechanism including power cuts surges etc Additional items not supplied by Future Automation although they may have been supplied together by the retailer Any 3rd party software products controlling y...

Page 5: ...ITIONING SA 10 SCREEN ADVANCE MOUNTING SA 11 SETTING THE MECHANISM IN OUT POSITIONS SA 12 SCREEN ADVANCE MOUNTING SAH 13 SCREEN ADVANCE MOUNTING SAH 14 SETTING THE MECHANISM IN OUT POSITIONS SAH 15 CO...

Page 6: ...UNIT 1 4 SCREEN ADVANCE UNIT 1 5 SCREEN ADVANCE UNIT HEAVY 1 6 PANEL MOUNT PLATES 2 CONTROL BOX 3 IR REMOTE CONTROL ITEMS NOT SHOWN ON PAGE SPS ACCESSORY PACK 2X AAA BATTERIES MULTI PACK NUTS BOLTS W...

Page 7: ...g attached stating the correct connecting socket on the control board e g AC1 DC2 Image 2 Below 5 Plug the green connector into the corresponding socket on the control board This plug is handed and wi...

Page 8: ...se yourself with mechanism operation Panel Drive Unit cams are factory set to the correct positions and should not be adjusted without first contacting a member of the Future Automation team 2 Set up...

Page 9: ...l to confirm all marks are level 2 Mark up the top position of the screen inside the enclosure along with a center line in preparation for display positioning Enclosure height should accommodate heigh...

Page 10: ...height between mounting plate and bottom of enclosure A block of MDF can be cut to this height to use as a guide left 3 Use appropriate fixings NOT INCLUDED to secure the mounting plates to the insid...

Page 11: ...of the unit to the two couplers at the top of the right hand panel 2 Loosen the two M5 x 35mm bolts and nuts to allow the telescopic end to extend to join to left panel Mechanism Mechanism 3 Re tight...

Page 12: ...CE POSITIONING SA Offer display to Screen Advance mechanism Measure from the top of the display to the key hole mount slot 2 1 The measurement taken can be used to correctly position mechanism inside...

Page 13: ...so that the SA can be freely supported inside the enclosure 5 6 3 Toggles Mount Bolts Remove the Screen Mount Plate by loosening the two Screen Mounting Toggles and lifting up and away 1 Take Screen A...

Page 14: ...and then manually pull out the mechanism 3 Adjust the SA Cams to ensure that the mechanism sits flush with the front panel mechanism 1 To change the OUT position move the outer Cam to adjust the advan...

Page 15: ...isplay to Screen Advance Heavy SAH mechanism Measure from the top of the display to the two largest mounting holes on the SAH Bracket Wall Plate 2 1 The measurement taken can be used to correctly posi...

Page 16: ...the two Uprights from the SAH and attach them to the display using the supplied fixings 1 Using the previous measurement for reference secure the SAH mechanism into the enclosure using the appropriate...

Page 17: ...ank length by loosening the bolts and slide to be longer shorter 3 There are two ways to adjust the advance distance of the mechanism 1 Slide the Top Mount Plate back for forward on the slots 2 Then y...

Page 18: ...together Labelled A to A 1 Inserts A A Each mechanism has its own set of wires that are control box inserts and block connectors 2 Each cable is labelled to show which set of connectors the block conn...

Page 19: ...ealment panel onto the mechanism It is attached to the runners with M6 x 10mm CSK bolts with washers 1 Use one fixing in each slot at one of the three mounting heights available 2 Offer the enclosure...

Page 20: ...Remove the mounting plates from the mechanism to attach the enclosure panel 1 Use the previous measurement as a guide to attach the mounting plates to the enclosure panel leaving 5mm of clearance arou...

Page 21: ...wo bolts shown in the detail view Do not fully remove them 1 Slide the switch plate up will make the panel travel higher 2 The panel will travel approximately 3 times the distance the switch plate mov...

Page 22: ...MENT The down position can be adjusted by moving the position of the mount plate in the slots on the mechanism Right 1 The down switch plate is factory set and should not be adjusted There is 60mm 2 4...

Page 23: ...the frame 4 Attach the screen uprights to the display and offer it to the mechanism 5 Make final adjustments to the display by altering the height that the display is fixed to the upright slots or ad...

Page 24: ...third party safety mechanism REPLACING MECHANISM BATTERIES The standard Future Automation Infrared IR remote control required x2 AAA batteries to operate These are provided with the mechanism in the A...

Page 25: ...trol box As Infrared IR control works over line of site the Infrared IR sensor must be directly viewable from what ever location the remote control is being used from Infrared IR Remote Control Button...

Page 26: ...affected cabinet thickness cabinet material or other electronic signals i e strong WIFI signals Radio Frequency RF Remote Control Button Layout IMPORTANT Pressing any button while the mechanism is mov...

Page 27: ...board then shorting pins 1 8 on this connector as shown in the Contact Closure Input Table below Confirmation of Contact Closure input will be shown by a single flash of the large green LED located on...

Page 28: ...the end of the control box RJ11 RJ25 PIN LAYOUT PIN 1 RX PIN 6 TX PIN3 4 GROUND PIN 2 RX PIN 3 TX PIN 5 GROUND SERIAL PIN LAYOUT RS232 INPUT TABLE RS232 PROGRAMMING DETAILS Baud Rate 9600 Stop Bit 1 P...

Page 29: ...NOTES...

Page 30: ...44 0 1438 833577 Email info futureautomation co uk Office Hours Mon Fri 8 00 to 17 30 GMT Saturday Sunday Closed NORTH AMERICAN OFFICE Address Enterprise Park 127 Venture Drive Dover NH 03820 Phone 1...

Reviews: