23
Automatic Control
Factory Default Setting = 8
APPENDIX E
Operation Switches Reference Page
Pot
Deadband
Value
in.
mm
0
0.0
0.0
1
0.1
2.5
2
0.2
5.1
3
0.3
7.6
4
0.4
10.2
5
0.5
12.7
6
0.6
15.2
7
0.7
17.8
8
0.8
20.3
9
0.9
22.9
A
1.0
25.4
B
1.1
27.9
C
1.2
30.5
D
1.3
33.0
E
1.4
35.6
F
1.5
38.1
On-Grade Deadband
(10)
Performance Options
(11)
Valve Gain
(12)
Distance from Deadband
to Full Blade Speed
Pot
Linear
Exponential
Value
mm
mm
0
(slow)
200
78
1
170
71
2
148
63
3
129
57
4
112
53
5
98
47
6
86
42
7
75
37
8
65
33
9
56
28
A
48
25
B
40
21
C
33
17
D
26
14
E
19
11
F
(fast)
12
8
Factory Default Setting = 8
Factory Default Setting = All OFF
2 Strike
Averaging OFF
2 Strike
Averaging ON
1
Receiver LED
Disable OFF
Receiver LED
Disable ON
2
Control Box
LED’s Bright
Control Box
LED’s Dim
3
Exponential Gain
Linear Gain