11
Automatic Control
CONTROL BOX - CONFIGURATION
Valve Set Up (1
VV
4)
-
Set Valve Minimum Correction
Set the machines throttle to normal operating RPM.
Place the blade approximately 1 foot (0.3 m) above the ground.
No laser is required.
RAISE Minimum Correction:
(switch 1 in ON position)
1. Toggle raise/lower switch to raise and hold.
2. If no blade movement, release switch. If there is movement, skip to step 5.
3. Toggle automatic/manual switch once to auto to increase VMC one unit.
4. Return to step 1.
5. Observe blade speed. Goal is 0.5 inches (13 mm) per second.
6. If blade speed is too slow, continue increasing VMC and checking blade speed.
If blade speed is too fast, toggle A/M switch towards manual to decrease VMC.
7. After proper VMC setting is obtained, note value.
8. Adjust DIP switch to OFF position.
LOWER Minimum Correction:
(switch 2 in ON position)
1. Toggle raise/lower switch to lower and hold.
2. If no blade movement, release switch. If there is movement, skip to step 5.
3. Toggle automatic/manual switch once to auto to increase VMC one unit.
4. Return to step 1.
5. Observe blade speed. Goal is 0.5 inches (13 mm) per second.
6. If blade speed is too slow, continue increasing VMC and checking blade speed.
If blade speed is too fast, toggle A/M switch towards manual to decrease VMC.
7. After proper VMC setting is obtained, note value.
8. Adjust DIP switch to OFF position.
Note:
It is advisable to log the various settings for each particular machine.