background image

12

GENERAL

Description

The following directions should enable 

the person responsible for the product, 

and the person who actually uses the 

equipment, to anticipate and avoid op-

erational hazards. The person responsi-

ble for the product must ensure that all 

users understand these directions and 

adhere to them.

Adverse Use

 ∙ Use of the product without instruction.

 ∙ Use outside of the intended limits.

 ∙ Disabling safety systems.

 ∙ Removal of hazard notices.

 ∙ Opening the product using tools, for 

example screwdriver, unless this is 

specifically permitted for certain func-

tions.

 ∙ Modification  or  conversion  of  the 

product.

 ∙ Use after misappropriation.

 ∙ Use of products with obviously recog-

nizable damages or defects.

 ∙ Use with accessories from other manu-

facturers without the prior explicit ap-

proval of FUTECH.

 ∙ Inadequate safeguards at the work 

site, for example when using on or 

near roads.

 ∙ Deliberate dazzling of third parties.

 ∙ Controlling of machines, moving ob-

jects or similar monitoring application 

without additional control and safety 

installations.

WARNING

Adverse use can lead to injury, malfunc-

tion and damage. It is the task of the 

person responsible for the equipment to 

inform the user about hazards and how 

to counteract them. The product is not 

to be operated until the user has been 

instructed on how to work with it.

LIMITS OF USE

Environment

Suitable for use in an atmosphere appro-

priate for permanent human habitation: 

not suitable for use in aggressive or ex-

plosive environments.

DANGER

Local safety authorities and safety ex-

perts must be contacted before working 

in hazardous areas, or in close proximity 

to electrical installations or similar sit-

uations by the person in charge of the 

product.

RESPONSIBILITIES

Manufacturer of the product

Laseto N.V., Belgium, BE0808.043.652, 

hereinafter referred to as FUTECH, is re-

sponsible for supplying the product, in-

cluding the user manual and original ac-

cessories, in a completely safe condition.

Manufacturers of non FUTECH 

accessories

The manufacturers of non FUTECH ac-

cessories for the product are responsi-

ble for developing, implementing and 

communicating safety concepts for their 

products, and are also responsible for 

the effective- ness of those safety con-

cepts in combination with the FUTECH 

product.

Person in charge of the product

The person in charge of the product has 

the following duties:

 ∙ To understand the safety instructions 

on the product and the instructions in 

the user manual.

 ∙ To be familiar with local regulations 

relating to safety and accident preven-

tion.

 ∙ To inform FUTECH immediately if the 

product and the application becomes 

unsafe.

Summary of Contents for DISTY40

Page 1: ...DISTY40 DISTY80 201 40 201 80 MANUAL...

Page 2: ...evice dur ing transportation Regularly inspect the accuracy of the instrument especially when starting any major square setting work You have sole responsibility for the accuracy of your work Do not u...

Page 3: ...Off button 12 Laser active 13 Referencepoint in front 14 Referencepoint at the back 15 Reference point positioning bracket 16 Max and Min measurement 17 Surface Volume 18 Indirect measurement Single p...

Page 4: ...n be adapted for the following measuring situations For measurements from an edge fold out the positioning bracket until it first locks in place corner of 90 For measurements from a corner open the po...

Page 5: ...each single measurements can be deleted and remeasured in series Reference The default reference setting is from the rear of the instument The display will show you Press the button to change the refe...

Page 6: ...ton and hold down this button until you hear a beep Then slowly sweep the laser back and forth and up and down over the desired target point e g into the corner of a room Press the button to stop cont...

Page 7: ...rs in the display Press the button to take the first measurement e g length Press the button to take the second measurement e g widht Press the button to take the third measurement e g height The resu...

Page 8: ...t All target points must be in a horizontal or vertical plane The best results are achieved when the instrument is rotated about a fixed point e g with the position bracket fully folded out and the in...

Page 9: ...al sode on the second link The calculated height on the third line Keep in mind that the lenght ofthe horizontal line is only 100 correct when a precise vertical measurement is performed Double indire...

Page 10: ...d third 90 measurement The results are now shown on the screen from top to bottom distance to first upper point distance to the second point distance from the measured horizontal point distance betwee...

Page 11: ...ge The Disty40 is limited to 40m the Disty80 to 80m At night or dusk and if the target is in shadow the measuring range without target plate is increased Use a target plate to increase the measurement...

Page 12: ...to counteract them The product is not to be operated until the user has been instructed on how to work with it LIMITS OF USE Environment Suitable for use in an atmosphere appro priate for permanent h...

Page 13: ...cted to mechanical shock for example blows or falling the product may be damaged or peo ple may sustain injury When setting up the product make sure that the accessories are correctly adapted fitted s...

Page 14: ...hazards The per son responsible for the product must ensure that all users understand these directions and adhere to them Products classified as laser class 1 class 2 and class 3R do not require lase...

Page 15: ...lly select ed components and crafted with the utmost care By that we can offer you an optimal quality If your device should however be defective due to faulty materials or a production error you can b...

Page 16: ...futechtools futech tools Facebook LinkedIn JOIN US futech tools com World Wide Web...

Reviews: