3. ADJUSTMENTS
3-18
3.5 DATA
CALIBRATION
Menu
The DATA CALIBRATION menu lets you offset speed, temperature and depth data to
further refine accuracy referring to the appropriate sensors.
Rotate the course control knob to select “DATA CALIBRATION” from the INSTALLATION
MENU, and then press the course control knob to show the DATA CALIBRATION menu.
PUSH MENU KEY TO RETURN
TO PREVIOUS MENU.
*: Actual value input.
STW:
0
% (7.5 kt)*
TEMP:
18.00 F (68.5 F)*
DEPTH:
0.0 ft (220 ft)*
WIND ANG:
-180.0 (- - - . - ) A
WIND SPEED:
-50 % (- -. - kt) A
Data calibration menu
3.5.1 STW (CALIBRATION)
Offset the speed through water data.
1. Rotate the course control knob to select “STW” from the DATA CALIBRATION menu.
2. Press the course control knob and the current value is circumscribed with a double
rectangle.
3. Rotate the course control knob to set offset (Setting range: -50% to +50%).
4. Press the course control knob to finish.
3.5.2 TEMP (CALIBRATION)
Offset the water temperature data.
1. Rotate the course control knob to select “TEMP” from the DATA CALIBRATION menu.
2. Press the course control knob and the current value is circumscribed with a double
rectangle.
3. Rotate the course control knob to set offset (Setting range: -18.00 to +18.00°F).
4. Press the course control knob to finish.
3.5.3 DEPTH (CALIBRATION)
Offset the depth data.
1. Rotate the course control knob to select “DEPTH” from the DATA CALIBRATION menu.
2. Press the course control knob and the current value is circumscribed with a double
rectangle.
3. Rotate the course control knob to set offset (Setting range: -30.0 to 300.0 ft).
4. Press the course control knob to finish.
Summary of Contents for NAVpilot-611
Page 6: ...iv This page is intentionally left blank...
Page 16: ...1 INSTALLATION OF UNITS 1 10 This page is intentionally left blank...
Page 57: ...30 Jun 08 R Esumi...
Page 58: ...30 Jun 08 R Esumi...
Page 59: ......
Page 60: ......
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ......
Page 65: ......
Page 66: ......
Page 67: ......