3. Open the left side cover on the scanner unit with the hex wrench (supplied).
4. Unfasten the cable gland for the multicore cable and remove the gasket and
flat washers.
5. As shown in Figure 2-9, slide the clamping gland, flat washers and gasket on
the multicore cable.
6. Fold back armor by 5 mm and pass it through the two flat washers as shown in
Figure 2-9.
Armor (folded back)
Gasket
Seal with putty
after tightening.
Vinyl sheath
Clamping gland
Flat
washer
Cable gland
Flat
washer
Flat
washer
Figure 2-9 Passing clamping gland, washers and gasket on the multicore cable
7. Shorten conductors considering their locations on the terminal board STB-1.
RTB-801
STB-1
Figure 2-10 Scanner unit, port side view
8. Confirm that armor is grounded between two flat washers.