2-6
How to attach NH connector
20mm
1
Insert NH connector
wire into NH connector
housing.
2
Cut shrink tubing
in 20 mm lengths and
slip onto each wire.
3
Solder connector
to signal cable.
4
Heat shrink
tubing with solder-
ing iron.
NH connector wire
Shrink tubing
NH connector
housing
Solder
HOW TO ATTACH NH CONNECTOR TO SIGNAL CABLE
Figure 2-6 How to attach NH connector
2.2 Scanner Unit
Fabricating multicore cable 660V-MPYCY-12/250V-MPYCY-
12 (JIS cable)
1. Shorten the multicore cable making the length from the cable gland to the cable
end inside the scanner unit 450 mm. Remove the vinyl sheath of the cable by
450 mm; the armor by 440 mm.
Armor
440 mm
450 mm
Conductors
,,,,,,,,,,,,,
,,,,,,,,,,,,,
,,,,,,,,,,,,,
,,,,,,,,,,,,,
,,,,,,,,,,,,,
,,,,,,,,,,,,,
,,,,,,,,,,,,,
,,,,,,,,,,,,,
,,,,,,,,,,,,,
,,,,,,,,,,,,,
,,,,,,,,,,,,,
,,,,,,,,,,,,,
,,,,,,,,,,,,,
Armor
Vinyl sheath
Core
φ
= 1.25 mm
2
Figure 2-7 Fabrication of multicore cable 660V-MPYCY-12/250V-MPYCY-12
2. Turn off the ANT MOTOR SW on the scanner unit.
ANT MOTOR SW
Multicore cable
(250V-MPYCY-12 or
660V-MPYCY-12)
Signal cable
(S03-74)
Figure 2-8 Scanner unit, bow view