4. POWER SUPPLY
Power supply & rated
100-240 VAC: 1.47 A – 0.89 A
Current
5. ENVIRONMENTAL CONDITION
Category of unit
Antenna unit: To be installed in a Exposed area
Others: To be installed in a protected area
Ambient Temperature
Complies with Inmarsat SDM and IEC60945 (Ed.4)
Antenna unit:
-25°C to +50°C
Communication unit: 0°C to +45°C
Handset:
0°C to +45°C
Relative Humidity
95% at 40°C (Inmarsat SDM 95 & IEC60945)
Waterproofing
Complies with IEC 60529;
Antenna Unit: IPX6
Communication Unit: IPX0
Handset: IPX0
Vibration
Complies with Inmarsat SDM and IEC60945
Motion
Roll: ± 30°/8s, Pitch: ± 10°/6s, Yaw: ± 8°/50s, Surge: ± 0.2G,
Sway: ± 0.2G, Heave: ± 0.5G, Rotation: 6°/s, Speed: 30 kt
6. COATING COLOR
Antenna Unit
Munsell N9.5
Communication Unit
Munsell N1.0
ISDN Handset
Munsell N1.0
Distress Alert Unit
Munsell N1.0