Maintenance and service
The camera is maintenance-free.
The glass surfaces of the lenses and protective panels must be cleaned as required.
Troubleshooting
Camera not in operation (no output signal)
Check wiring; check voltage supply (power supply
unit)
Camera in operation, but no picture
Check wiring; configure or adjust lens correctly
Camera in operation, but picture out of focus
Adjust back focus and lens.
A complete FAC 940 Service Manual can be obtained from your local Funkwerk office under
order no. 0043041-969.01.
Use the exchange pool at your local Funkwerk office if repairs are needed.
Service address: Funkwerk video systeme GmbH
Thomas-Mann-Str. 50
D-90471 Nürnberg
Tel.: +49 (0)911 75884-0
Fax: +49 (0)911 75884-100
Connector pin assignments of D-SUB system connector
Table 1
1
Remote control RXD_A
9
+U_BATT
2
Remote control RXD_B
10
ST2
3
ST1
11
GENLOCK GND
4
Remote control TXD_B
12
Remote control TXD_A
5
GENLOCK/LINE LOCK
13
-UBATT
6
-(C)VBS/C
14
GND
7
(C)VBS
15
GND
8
+(CVBS)/Y
View of the pins
Table 2: Pin assignments of lens connector
Auto iris lens
Galvanometer
Kangaroo lens
ER lens
Connector pin 1
+12 V DC
- Damping
+12 V DC
Connector pin 2
+ Damping
Connector pin 3
Video signal
+ Drive
Control
Control
Connector pin 4
GND
- Drive
GND
GND
21
FAC 940
Summary of Contents for FAC 940
Page 23: ...23 FAC 940 ...