System
bintec User’s Guide
15
Submenu Schedule & Monitor
4
Source IP
The IP address that the gateway uses as
source address of the packet sent to the host to
be monitored.
DownAction
Defines how the status of the gateway inter-
faces selected in
F
IRST
I
F
I
NDEX
and
R
ANGE
is set
if all hosts in a group are not reachable. Possi-
ble values:
■
down
: Interfaces are deactivated, i.e. ad-
min status is set to
down
. (Default value)
■
none
: No action, i.e. admin status is set to
up
.
■
up
: Interfaces are activated.
The status of the interfaces is
set
to the original
value again when at least one host in a group
can be reached again.
Note:
D
OWN
A
CTION
must be configured identi-
cally within a group!
FirstIfIndex
Defines the first interface of an interface range
in the gateway, for which the action (
down
or
up
) defined under
D
OWN
A
CTION
is to be exe-
cuted.
Possible values:
100
..
65536
Default value:
10001
Interfaces with indices from
10001
to
14999
are
provided for dialup connections to WAN part-
ners. You can find the indices of the interfaces
with, for example, the command
ifstat
.
Field
Description
Summary of Contents for bintec R230a
Page 4: ...2 bintec User s Guide System ...
Page 8: ...1 6 bintec User s Guide System System Menu ...
Page 14: ...3 12 bintec User s Guide System Submenu External System Logging ...
Page 34: ...4 32 bintec User s Guide System Submenu Schedule Monitor ...
Page 40: ...6 38 bintec User s Guide System Submenu Time and Date ...
Page 44: ...42 bintec User s Guide System V Value inactive 30 Variable 22 30 ...