4
18
bintec User’s Guide
System
Submenu Schedule & Monitor
Table 4-2:
Fields in
K
EEPALIVE
M
ONITORING
interfaces
menu
4.2
Submenu Event Scheduler
(Time & SNMP)
Your gateway is equipped with an event scheduler, which makes it possi-
ble to modify existing MIB variables as soon as a certain event (e.g. time-
dependent) occurs.
In general, any event in the MIB can be defined as the trigger.
FirstIfIndex
Defines the first interface of an interface range
in the gateway, for which the action (
down
or
up
) defined under
D
OWN
A
CTION
is to be exe-
cuted.
Possible values:
100
..
65536
Default value:
10001
Interfaces with indices from
10001
to
14999
are
provided for dialup connections to WAN part-
ners. You can find the indices of the interfaces
with, for example, the command
ifstat
.
Range
Defines the range of interfaces in the gateway,
for which the action defined under
A
CTION
is to
be executed.
If you set
F
IRST
I
F
I
NDEX
=
10001
and
R
ANGE
=
0
,
only the interface with the index
10001
is
affected.
If you set
F
IRST
I
F
I
NDEX
=
10001
and
R
ANGE
=
4999
(default value), the interfaces with the
indices
10001
to
14999
are affected.
Field
Description
Summary of Contents for bintec R230a
Page 4: ...2 bintec User s Guide System ...
Page 8: ...1 6 bintec User s Guide System System Menu ...
Page 14: ...3 12 bintec User s Guide System Submenu External System Logging ...
Page 34: ...4 32 bintec User s Guide System Submenu Schedule Monitor ...
Page 40: ...6 38 bintec User s Guide System Submenu Time and Date ...
Page 44: ...42 bintec User s Guide System V Value inactive 30 Variable 22 30 ...