ft635ule_eng (21.06.2012)
- 36 -
- 37 -
ft635ule _eng(21.06.2012)
Kompetent für Elektroniksysteme
Kompetent für Elektroniksysteme
By selecting 'A' the poti setting is started.
#A
Which poti is to be adjusted?
1: input of radio
2: output to radio
3: input of discriminator
4: output to SUBout
x: end
Selecting '!' allows the setting of the radio input.
Poti adjusted (input of radio)
Enter 1000Hz at radio input with nominal level.
Adjust at internal measuring point ‚MP1‘ to 300mV .
Starting value: 047 (min:000 max:255) level: 0002 mV nominal
level: 300 mV
activate:
<+> : poti+1
<*> : poti+10
<-> : poti-1
<_> : poti-10
<a> : auto-adjustment
<p> : program
<x> : termination
currently: 047 level: 0002 mV
Selecting '2' allows the setting of the radio input
poti adjustment (output to radio)
starting value: 053 (min:000 max:255)
activate:
<+> : poti+1
<*> : poti+10
<-> : poti-1
<_> : poti-10
<p> : program
<x> : termination
currently: 053